Installation procedures, Distance gauge – Garmin GMR 18/24 User Manual

Page 5

Advertising
background image

GMR 18/24 Marine Radar Installation Instructions



Installation Procedures

The following order of mounting the scanner and attaching the power and network cables may vary depending on the installation location and

mount used.

Mounting the Scanner

1. When a suitable mounting location is determined, verify that the mounting hole locations are aligned fore and aft, and use the included

mounting template or reference Figure 1 to drill four 9.5 mm (

3

/

8

") mounting holes. (This step is not necessary if you are using a pre-drilled

Garmin compatible or Raymarine

®

mount.)

2. Align the notch and locking ring on the power cable to the power connector. Press the 2-pin power cable to the power connector and the

RJ-45 marine network cable to the RJ-45 socket (Figure 2). Turn the power cable locking ring clockwise until it stops. Tighten the RJ-45

locking ring clockwise until it is firmly sealed.

3. The power and network cables may be pressed into any of the five guide grooves molded into the bottom of the scanner case and

secured under the cable hold-down plate (Figure 2). Avoid excessive bending or twisting of the cables. See the following “Cable Runs”

section for more information.

4. Position the scanner on the mounting surface with the triangular mark on the case aligned to the front of the vessel. Apply a bead of

marine sealant around each of the mounting holes on the mounting surface.

5. Install the four (4) M8 x 1.25 x 60 threaded rods into the Mounting Holes on the bottom of the scanner. There should be no more than

50 mm (2") extruding from the scanner when they are installed properly.

6. Fasten the scanner to the mounting surface using the M8 x 1.25 x 60 threaded rods (installed in the previous step), spring washers, flat

washers, and M8 Hex nuts as shown in Figure 3.

The nuts should be torqued to between 13.7-18.6 N-m (10-14 lb ft).

Note: The supplied M8 x 1.25 x 60 threaded rods can be used on mounting thicknesses of 5-30 mm (

3

/

16

" - 1

3

/

16

") (recommended). For surfaces

over 30 mm (1

3

/

16

"), locally supplied longer threaded rods are needed.

Wire Gauge Table

Distance

Gauge

2 meters (6

1

/

2

ft)

16 AWG

4 meters (13 ft)

14 AWG

6 meters (19 ft)

12 AWG

Figure 1

141.5 mm

(5

9

/

16

")

"

9.5 mm

(

3

/

8

")

"

2 mm

(9

5

/

2

")

"

Ship's Bow

Figure 2

Mounting

holes

Power

connector

Network

connector

Cable routing

options

Plate

Mounting

bracket

Flat

washer

Spring

washer
M8 x 60

threaded

rod

Scanner

M8 nut

Figure 3

Advertising