Grandstream Networks 386 User Manual

Page 24

Advertising
background image

HandyTone-386 User Manual

Grandstream Networks, Inc.

24

Firmware Key:

(in Hexadecimal Representation)

Onhook Threshold:

800 ms

FXS Impedance:

600 Ohm (North America)

Caller ID Scheme:

Bellcore (North America)

Onhook Voltage:

36V

Polarity Reversal:

No

Yes (reverse polarity upon call establishment and

termination)

NTP Server:

time.nist.gov

(URI or IP address)

Syslog Server:

Syslog Level:

NONE

Update

All Rights Reserved Grandstream Networks, Inc. 2005




Admin Password

Administrator password. Only administrator can configure the “Advanced
Settings” page. Password field is purposely blanked for security reason after
clicking update and saved. The maximum password length is 25 characters.



Home NPA

Local area code for North American Dial Plan.

Layer 3 QoS

This field defines the layer 3 QoS parameter which can be the value used for
IP Precedence or Diff-Serv or MPLS. Default value is 48.

Layer 2 QoS

Layer 2 QoS settings. Default setting is blank. Other VLAN supported
equipments required if configured these settings.

No Key Entry
timeout

Default is 4 seconds. User can short or extend that depends on digits dialed

STUN Server

IP address or Domain name of the STUN server.

Keep-alive interval

Default is 20 seconds. The interval of sending dummy UDP packet to keep
NAT “pin hole” open.

Use NAT IP

NAT IP address used in SIP/SDP message. Default is blank.

Firmware Upgrade
and Provisioning

Default method is HTTP. Firmware upgrade may take up to 10 minutes
depending on network environment. Do not interrupt the firmware upgrading
process.