Graco Inc. Hydra Clean 800-672 User Manual

Page 5

Advertising
background image

5

308-523

INSTALLATION

Figure 1

SPRAY

GUN

SPRAY

HOSE

QUICK

COUPLER

QUICK

COUPLER

INLET WATER

CONNECTION 3/4”

GARDEN HOSE

HIGH

PRESSURE

HOSE

CONNECTION

HIGH PRESSURE

HOSE CONNECTION

INLET WATER

CONNECTION 3/4”

GARDEN HOSE

2040

1535

Check for Shipping Damage

Check the unit for any damage that may have occurred
in shipping. Notify the carrier immediately if there is
any damage.

Set Up

If you are using a downstream chemical injector, install it
between the pump unloader and the high pressure
hose, using the quick couplers provided.

Connect the high pressure hose between the pump
outlet and the gun inlet. Both of these connections are
made with quick couplers.

CAUTION

Up to 100 ft (30 m) of high pressure hose may
be used. Longer hoses may affect sprayer
performance, and chemical injector
performance, if used.

Install the appropriate spray tip on the wand. See
Installing and Changing Spray Tips. If you are using a
sandblaster kit, see its separate manual for installation
instructions.

Connect to Water Supply

CAUTION

Before attaching to the water supply, check
your local plumbing code regarding cross–
connection to the water supply. A backflow
preventer, P/N 801–133, is available to prevent
backflow of contaminated water into the fresh
water supply. Install it upstream from the pump.

If inlet water pressure is over 60 psi (4.1 bar) a
regulating water valve, P/N 800–258, must be
installed at the garden hose connection.

Do not exceed 160

_

F (70

_

C) inlet water

temperature.

Connect a hose with at least a 3/4 inch (19 mm) ID from
the water supply to the unit’s 3/4 inch garden hose inlet.
The supply hose should not be more than 50 ft (15 m)
long.

NOTE:

The water source at the unit

must have a

minimum flow rate equal to that of the unit (see
Technical Data, inside back cover).

Advertising