Reassembly – Graco ROTOFLEX 309793 A User Manual

Page 3

Advertising
background image

RotoFlex Pump Repair Kit

309793 A

3

Reassembly

Reinstall RotoFlex Pump hose on plate.

1.

Kink hose as shown,
making sure dots
located on hose fitting
face each other.

2.

Slide hose onto plate
as shown below, mak-
ing sure plate slides
into slot between hex
fitting on end of hose.

3.

Align dots located on hose fitting, making sure they
are facing each other at all times to ensure the hose
does not twist during reinstallation.

4.

Reposition plate, aligning hex fittings with enclosure
openings.

5.

Remove wood block support under motor.

6.

Tighten bolt. As bolt is tightened the plate will snug
back into place.

7.

Replace shroud (6 bolts).

8.

Replace hopper.

9.

Break in new pump by running dry or with warm
water for 3-5 minutes.

ti3127a

DOTS

ti3125a

ti3084a