Gianni Industries PBA-860 User Manual

Exit, Pba-860tdi micro switch bar, Door loop-dl-200

Advertising
background image

EXIT

PBA-860TDI

DM-CA-PBA Ver. G Published on 2009.03.17

PSU-100-UL
Power Supply Units

EM-NH300
Electromagnet Lock

DL-200
Door Loop

KS-750
Key Switch

PBA-860TDI Micro Switch Bar

The PBA-860TDI is a micro switch push bar that is easy to install and specially designed to prevent unauthorized use of
emergency exits and lower the risk of theft and burglary in airports, hotels and other public places. It can also be used in
hospitals, nursing homes or health centers to prevent unauthorized access to restricted areas by patients.

The PBA-860TDI features a 95dB buzzer alarm sounds when someone pushes the bar. It also activates an output
signal that can be used to remotely alert security of use of the emergency exit. The exit will then unlock after a time delay,
which is adjustable between 1~30 seconds during which the buzzer will continue to sound. The PBA-860TDI is available
in satin silver, red and green.

Optional outdoor accessories: Digital code-operated keypad – DG-101

Key switch-KS-750

EM Series Electromagnetic Locks

Optional indoor accessories: Power supply unit - PSU-100UL

Micro-Switch Push Bar
with Time Delay

PBA-860TDI Control PC Board

Operation Notes:

Door loop-DL-200

N.O. jumper

N.C. jumper

95dB buzzer

P1 strike time jumper setting

3 seconds

Emergency signal input

P3 Emergency signal input
N.C/N.O jumper setting

Strike time (time required for the push bar to be held to activate) and jumper for N.C./N.O.
settings can be customized through P1 and P2 respectively.

Once the strike time has passed, the alarm buzzer is activated. A further time delay, adjustable
between 1 and 30 seconds, will pass before the door is then unlocked. This allows security to
react to any possible unauthorized use of the emergency exit, resetting the push bar if necessary
to prevent the door from unlocking.

Once the alarm buzzer is activated it will continue until the device is reset. It can be reset
either remotely with a switch or locally with a key switch. The door will remained unlocked
until the push bar is reset.
An emergency break-glass type call point can be connected to the ‘CUT INPUT’. This would
bypass all time delays to immediately unlock the door. The jumper for N.C./N.O. settings for
this emergency signal can be customized through P3.
The buzzer and signal output are activated simultaneously such that the signal output can be
used from remote monitoring. The current draw of the output relay is 3A/12VDC or 1A/125VAC.

For safety reasons, the electromagnetic locks used on this type of installation should be fail-safe
and it is recommended to use UL listed uninterruptable power supplies (UPS) in case of power cuts.

Red (N.C.)

Black (COM.)

White (N.O.)

P2

N.C./N.O. jumper setting

N.O. jumper

N.C. jumper

Bar Length: 860mm

No. 13, Zhongxing Rd., Tucheng Dist., New Taipei
City 236,Taiwan (R.O.C.)
Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876
E-Mail: [email protected]