background image

5 308-505

INSTALLATION

Figure 1

SPRAY

GUN

SPRAY

HOSE

QUICK

COUPLER

QUICK

COUPLER

INLET WATER CONNECTON

3/4” GARDEN HOSE

HIGH

PRESSURE

HOSE

CONNECTION

HIGH PRESSURE

HOSE CONNECTION

INLET WATER

CONNECTON 3/4”

GARDEN HOSE

2040

1535

Check for Shipping Damage

The unit should be checked for any damage that may

have occurred in shipping. Any damage should be noted

and the

carrier notified immediately.

Set Up

If you are using a downstream chemical injector, install it

between the pump unloader and the high pressure

hose, using the quick couplers provided.

Connect the high pressure hose between the pump

outlet and the gun inlet. Both of these connections are

made with quick couplers.

CAUTION

Up to 100 ft (30 m) of high pressure hose may

be used. Longer hoses may af

fect sprayer

performance, and chemical injector

performance, if used.

Install the appropriate spray tip on the wand. See

Installing and Changing Spray Tips. If you are using a

sandblaster kit, see its separate manual for installation

instructions.

Connect to Water Supply

CAUTION

Before attaching to the water supply , check

your local plumbing code regarding cross–

connection to the water supply . A backflow

preventer P/N 801–133 is available to prevent

backflow of contaminated water into the fresh

water supply. Install it upstream from the pump.

If inlet water pressure is over 60 psi (4.1 bar) a

regulating water valve P/N 800–258 must be

installed at the garden hose connection.

Do not exceed 160 _ F (70_ C) inlet water

temperature.

Connect a hose with at least a 3/4 inch (19 mm) ID from

the water supply to the unit’s 3/4 inch garden hose inlet.

The supply hose should not be more than 50 ft (15 m)

long.

NOTE: The water source at the unit must have a

minimum flow rate equal to that of the unit (see

Technical Data, inside back cover).