Warning, Side venting – GE UPVH880 User Manual

Page 28

Advertising
background image

WARNING –

BEFORE

PERFORMING THIS EXHAUST INSTALLATION,
BE SURE TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR HANDS
AND ARMS FROM SHARP EDGES WHEN
WORKING INSIDE THE CABINET. BE SURE
TO WEAR GLOVES.

EXHAUSTING THE DRYER (cont.)

Installation Instructions

28

SIDE VENTING:

Dryer Exhaust to right of cabinet for Electric
models only.
Dryer Exhaust to left of cabinet for Gas and
Electric models.

Detach and remove the bottom, right or left side
knockout as desired. Remove the screw inside the
dryer exhaust duct and save. Pull the duct out of
the dryer.

Remove
screw
and save

Remove desired
knockout (one only)

Fixing hole

Cut the duct as shown and keep portion A.

TAB LOCATION

Bend tab
up 45°

Through the rear opening, locate the tab in the
middle of the appliance base. Lift the tab to about
45°, using a flat blade screwdriver.

ADDING A NEW DUCT

Reconnect the cut portion (A) of the duct to the
blower housing. Make sure that the shortened duct
is aligned with the tab in the base. Use the screw
saved previously to secure the duct in place
through the tab on the appliance base.

ADDING ELBOW AND DUCT FOR EXHAUST
TO LEFT OR RIGHT SIDE OF CABINET

Insert the 4

elbow through the rear opening and

connect the elbow to the dryer internal duct.

Insert the 4

duct through the side opening

and connect it to the elbow.

CAUTION: Be sure not to pull or damage
the electrical wires inside the dryer when
inserting the duct. A slight interference may
occur between the exhaust and the wire
components.

Portion “A”

Left side
exhaust

Fixing hole

Apply duct tape as

shown on the joint
between the dryer
internal duct and
the elbow, and also
the joint between the
elbow and the side duct.

CAUTION: Internal duct
joints must be secured with tape; otherwise,
they may separate and cause a safety hazard.

Internal duct

Duct tape

Not for gas

A

13

3

8

Right

Left

Bottom

Rear opening

Side opening

Advertising