Installation Instructions

REQUIREMENTS FOR ALCOVE OR

CLOSET INSTALLATION

Your dryer is approved for installation in

an alcove or closet, as stated on a label on

the dryer back.

The dryer MUST be vented to the outdoors. See

the EXHAUSTING THE DRYER section.

Minimum clearance between dryer cabinet and

adjacent walls or other surfaces is:

0″ either side
3″ front and rear

Minimum vertical space from floor to overhead

shelves, cabinets, ceilings, etc., is 52″.

Closet doors must be louvered or otherwise

ventilated and have at least 60 square inches

of open area equally distributed. If the closet

contains both a washer and a dryer, doors must

contain a minimum of 120 square inches of open

area equally distributed.

The closet should be vented to the outdoors

to prevent gas pocketing in case of gas in the

supply line.

No other fuel-burning appliance shall be

installed in the same closet with the dryer

(gas models only).

NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT

THE REAR OF THE DRYER, MINIMUM CLEARANCE

FROM THE WALL IS 5.5 INCHES.

BATHROOM OR BEDROOM

INSTALLATION

The dryer MUST be vented to the outdoors. See

EXHAUSTING THE DRYER.

The installation must conform with local codes or,

in the absence of local codes, with the NATIONAL

ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric

dryers) or NATIONAL FUEL GAS CODE, ANSI Z223

(for gas dryers).

MOBILE OR MANUFACTURED HOME

INSTALLATION

The installation must conform to the

MANUFACTURED HOME CONSTRUCTION & SAFETY

STANDARD, TITLE 24, PART 32–80 or, when such

standard is not applicable, with AMERICAN

NATIONAL STANDARD FOR MOBILE HOME,

NO. 501B.

The dryer MUST be vented to the outdoors with

the termination securely fastened to the mobile

home structure. (See EXHAUSTING THE DRYER.)

The vent MUST NOT be terminated beneath a

mobile or manufactured home.

The vent duct material MUST BE METAL.
FOR GAS MODELS ONLY: KIT 14-D346-33 MUST be

used to attach the dryer securely to the structure.

FOR GAS MODELS ONLY: The vent MUST NOT be

connected to any other duct, vent or chimney.

Do not use sheet metal screws or other

refastening devices which extend into the interior

of the exhaust vent.

Provide an opening with a free area of at least

25 sq. in. for introduction of outside air into the

dryer room.

16

RESIDENTIAL GARAGE INSTALLATION

Dryers installed in residential garages must be

elevated 18 inches (46cm) above the floor.