ENGINE APPLICATION MANUAL

GM Powertrain

Gasoline 4.3L V6 90 Degree

Revised: 08/15/2000

File: c:\data\manuales\v6-truck\am43v6#3.doc

Contact:Luis Nespolo - (248) 857-1558

Printed: 8/15/00

57

3.3.2 GMPT interface with Air Induction System

3.3.2.1 Air Requirement

Figure: 3.3.2.1-I 4.3L V6 90 Degree Engine Air Requirements

3.3.2.2 Air Flow Path

The air flow path in the vehicle at the air inlet of the air induction system shall not be
obstructed with vehicle components that will cause loss of pressure or flow disturbance.

All performance parameters specified in paragraph: 2.3.2.1 were measured with a maximum
air restriction of 1” of Hg.

As reference in table 3.3.2.1 - I, development power and torque data is shown to illustrate
the order of magnitude that may result as increasing the induction restriction.

RPM

L35

L35

Units

Truck

Marine

Application

Application

800

23.8

24.9

gr/sec

1200

37.8

39.3

gr/sec

1600

51.8

52.7

gr/sec

2000

65.8

67.4

gr/sec

2400

81.3

82.9

gr/sec

2800

97.7

99.0

gr/sec

3200

113.7

116.3

gr/sec

3600

128.8

130.5

gr/sec

4000

143.3

142.3

gr/sec

4400

154.7

154.0

gr/sec

4800

160.9

165.1

gr/sec

5200

163.7

175.0

gr/sec

Table 3.3.2.1 - I

4.3L V6

Development Peak Power and Torque Levels

Induction Restriction *

Induction

Torque

Power

Restriction

(Lb.-Ft)

(Hp)

1” Hg.

264

200

1.2” Hg.

262

198

1.4” Hg.

260

196

1.6” Hg.

258

194

* Exhaust backpressure held at 11” Hg.