-21-

Table Movement

The table height can be adjusted manually or with

the digital key pad and motor (see

Figure 16).

Manual Table Movement: Turn the handwheel
located under the front of the infeed table for
manual table positioning.

Motorized Table Moveme

nt:

Press the TABLE

UP or TABLE DOWN key once for motorized table
positioning in 0.005" (0.125mm) increments.

Numerical Key Pad

:

Enters the position of sand-

ing depth (See

Page 23

).

Metric or Standard Ke

y:

Press and hold the

SET button for 3 seconds to calibrate display at
the current board thickness (

Page 27

); or press

and hold key for 10 seconds to toggle the display
between metric and standard measurement.

Table Start Ke

y:

Moves table to a preset sand-

ing depth.

Table Stop

Key:

Stops table movement imme-

diately.

Digital Displa

y:

Shows final table sanding

depth.

The dial attached to the side of the feed belt
gear box (

Figure 17) adjusts the feed rate of the

sander.

Note: Never adjust the feed rate dial unless the
conveyor belt is running, otherwise you can dam-
age the control.

Changing Feed Rat

e:

Turn the dial clockwise to

decrease the feed rate and counterclockwise to
increase it.

Determining Ideal Feed Rate

s:

Softwoods typi-

cally require a faster feed rate than hardwoods;
however, there is no definitive rule to follow when
determining the best feed rate. As a general rule,
always start with the slowest feed rate and work
your way up. We always recommend testing
the feed rate using scrap wood similar to your
workpiece. Be sure to monitor the amperage
meter when adjusting the feed rate. Decrease
the feed rate if the load begins to slow the motor
RPM to damaging levels.

Adjusting Feed Rate

Figure 17. Feed rate dial.

Figure 16. Keys for adjusting the table height.

NOTICE

The thickness gauge is pre-calibrated from

the factory; however, correct calibration

should be verified.

Table

UP

Table Down

Metric or

Standard Key

Table

Stop

Table

Start

Digital Display

Numerical

Key Pad

Feed Rate

Dial

Advertising