RS-232 SERIAL CONTROL COMMANDS

#DDCTODS Function

The #DDCTODS function routes the input DDC to the downstream EDID (pass-
through mode).

Syntax:

#DDCTODS

Parameters:

None

#DDCTOLO Function

The #DDCTOLO function routes the input DDC to the local EDID.

Syntax:

#DDCTOLO

Parameters:

None

#DEF Function

The #DEF function set the Switcher to the factory default settings.

Syntax:

#DEF

Parameters:

None