Generac Power Systems 5466 User Manual

21 light remote annunciator, Standby generator accessories, Liquid-cooled generator sets

Advertising
background image

ENVIRONMENTAL SPECIFICATIONS

Operating Temperature .......................................................................................................................................................................... -25 º C to 60 º C

Humidity ............................................................................................................................................................................... 0 to 95% Non-Condensing

Power Supply ..........................................................................................................................................................................................+12 or +24 VDC

Power Usage ............................................................................................................................................................................................ 6 Watts typical

Power Supply .......................................................................................................................................................................................Generator Battery

Communication Line .......................................................................................................................... RS485 fully isolated twisted pair cable with shield

Maximum Cable Length .................................................................................................................................................................................... 4000 feet

Relay Output .............................................................................One NO contact (Engergized when annunciator is powered and no faults are present)

Relay Contact Rating .............................................................................................................................................................................. 30 VDC, 1 amp

STANDBY GENERATOR ACCESSORIES

21 Light Remote Annunciator

Liquid-Cooled Generator Sets

Model 5465
Model 5466
Model 5464

The Remote Annunciator Panel provides remote monitoring and
annunciation of up to 18 generator parameters using LED’s located on
the annunciator keypad. It also provides two system level warnings which
are System Ready and Communications OK.
The Relay panel has up to 8 selectable functions on form A relays,
and multiple relay panels can be connected for all 18 generator
parameters.

The specific faults can be selected using either the DIP switches located
on the annunciator circuit board or through a computer via the RS232
connection on the circuit board. All relays are energized on power up and
open during a fault condition.
Communication is via a RS485 serial data link and power is supplied by
the generator battery (+12 VDC or +24 VDC)
Note: These units are only compatible with the H-series generator
controller (70-150 kW)

DESCRIPTION