Programming, Programming guidelines, Transmitter programming – GE NETWORX NX-548E User Manual

Page 4: Add transmitters, Table 4. tripping transmitters

Advertising
background image

NetworX NX-548E Receiver

Installation Instructions

4

Programming

This section describes how to program the units.

Programming guidelines

Use the following programming guidelines:

• NX-4 and NX-6 control panels can have receivers added

with zones that overlap those contained in the control panel.
No hardware expanders can be used.

• NX-8 control panels can have expansion zones (hardwire or

wireless) set the same as those contained in the control
panel. To do this you must disable the onboard control panel
zones in panel location 37. All zone expansion modules
must not overlap any blocks of 8 zones.

• All other control panels can have wireless zones added to

any zone. If a hardwire input (on either the control panel or
hardwire expander) is also present on the same zone as an
enabled wireless zone, the wireless transmitter takes
priority.

Transmitter programming

When programming wireless transmitters into the receiver, you
can set various options and partitions for each transmitter. These
settings appear in segments of each programming location.
Use Table 5 on page 7 to record zone assignments and settings.
Be sure to circle where each zone resides:

RM. Receiver module

HE. Hardwire expander

P. Panel

This gives you all the programming information in one place to
facilitate the programming process.

Zone locations 1 to 192

Zone locations 1 to 192 are not numbered in Table 5 on page 7
since these locations vary depending on location 194, Receiver
zone bank setting.

Note:

The default settings shown for segments 1 and 2 in the first
zone location apply to all zone locations.

Add transmitters

LCD touchpads will display instructions when accomplishing tasks.
To add transmitters, do the following:
1.

Enter * 8 at the keypad. On LED touchpads, the five func-
tion lights start flashing.

2.

Enter the program code (factory default is 9 7 1 3). On LED
touchpads, the service light flashes and the five function
lights change from flashing to on steady.

3.

Enter the DIP switch setting module number and press #.
On LED touchpads, the Armed LED turns on, indicating the
control panel is waiting for a programming location entry.

4.

For new installations, enter 9 1 0 # to load factory defaults
and clear any unwanted information in memory.

5.

For new installations, set the receiver zone bank setting in
location 194 to determine the starting zone number for the
specific receiver. This applies only to NX-8E. This must be
set before learning sensors
. For example, if location 194 is
set to 3, the first available location is 25. The total number
of available locations depends on the zone limits for both
the panel and receiver.

6.

Enter 0 # to enter the sensor learning location. On LED
touchpads, the Ready LED turns on and the Armed LED
turns off.

7.

Enter the zone number (1 through 192) and press *. Three
beeps from the keypad indicate an entry error. This occurs if
you enter a transmitter number that is not within the
receiver’s zone block or if the location already has a sensor
learned into it.

Note:

If you change your mind about your entry, terminate
programming by entering 0 # 0 * and start over at
step 6.

8.

Trip the desired transmitter (within 250 seconds) as
described in Table 4. Listen for the ding dong for confirma-
tion

.

Note:

For specific instructions on tripping a transmitter,
consult the transmitter’s manual.

9.

To program remaining transmitters, repeat steps 6 to 8.

10. To exit program mode, press EXIT EXIT.
11. Confirm that the zone types and partition assignments are

set correctly in the control panel. Refer to the control panel
installation manual for instructions on how to set zone types
and partition assignments.

Note:

When an 80-bit device is added, Feature 6 of Segment 1
(see Table 5 on page 7) is turned on. But when a 63-bit
device is added on a zone location that previously had an
80-bit device, make sure to turn off Feature 6 of Segment 1.

Table 4.

Tripping transmitters

Transmitter

Action

Door/window, shock, glass

guard, freeze, UFT (Universal

Fire Transmitter)

Activate tamper switch by removing cover.

Door/window with external

contact

Activate tamper switch by removing cover.
Feature 4—Input option 1, must be on.

Recessed door/window

Activate tamper switch by removing circuit

board until tamper switch is exposed.

Micro door/window and
Micro recessed door/window

Refer to the installation instructions for the

specific sensor for activation information.

SlimLine door/window

Remove cover, then press the button on

the top of the sensor, or activate the

tamper switch by removing the cover.

PIR

Activate tamper switch by removing back

plate from PIR.

Smoke detector without

tamper switch

Press and hold the test button.

Smoke detector with tamper

switch

Trip the tamper switch. Feature 4—Input

option 1, must be on.

Heat detector

Press, then release the tamper switch.

Single button panic

Press and hold the button.

Dual button panic

Press and hold both buttons together.

Keyfobs

Press and hold the lock and unlock buttons

together.

Repeater

Press, then release the tamper switch.