Installation:

See rough-in drawings in this manual for dimensions and locations of
electric and water input.

Set-Up/Position

1) Remove the brewer from the packing material and attach its legs.

2) Position the brewer on a strong, stable table or counter. Check the

level front to back and side to side. Adjust the legs to the correct level.

IMPORTANT:
THE PERSON INSTALLING THIS APPLIANCE IS RESPONSIBLE
FOR ENSURING THAT ELECTRIC AND WATER CONNECTIONS
MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC
CODE, NATIONAL PLUMBING CODE, AND ANY LOCAL
ORDINANCES.

The electric and water hook-up locations are behind the front panel.
Remove the four screws fastening this panel for access to these
connections.

Table of Contents

Installation and Start-up ....................................... 1-2
Operation .......................................................... 3
Adjustments ........................................................ 4-7
Care and Cleaning ............................................... 8-9
Service ............................................................... 9-10
Troubleshooting

Filling Problems .................................... 11
Heating Problems ................................. 12
Brewing Problems ................................ 13

Parts Illustrations

Models P300E & P400E ....................... 14
Model RAP400E ..................................... 15

Model RAPS400E ................................... 16

VSB-400................................................ 17
Shuttle CS-LL .......................................... 18

Rough-In Drawings

Model P-300.......................................................... 19
Model P-400 ......................................... 20
Model RAP-300 ......................................... 21
Model RAP-400 ........................................ 22
Model RAPS-300 ....................................... 23
Model RAPS-400 ..................................... 24
VSB-300 .................................................. 25
VSB-400 ................................................ 26

Wiring Diagrams

P300E/P400E with 1 Batch Timer ......... 27
P300E/P400E with 2 Batch Timer........ 28
RAP300E/RAP400E................................29
RAPS300E/RAPS400E........................30
Drawing #091-548 .................................31
Drawing #091-182 ....................................32

Warranty ................................................................... 36

Water Hook-up

1) The water line may enter through holes on the rear or the bottom of the brewer. Use the right hand opening for water.
2) Use 3/8" copper or flexible water line to prevent strain. Do not use low temperature plastic tubing. The connection

to the fill valve is 3/8" flare.

3) Water line pressure must be from 30 to 70 psi.
4) Hot (up to 160°F) or cold water may be used. Hot water offers faster recovery between brews.
5) Install a shut-off valve near the brewer.
6) Installing a filtering system can improve the taste of brewed coffee and extend the life of the brewer. If your water

has high calcium (lime), chlorine, or iron content, this is especially important. The filter should be the lime inhibiting
type if cold water is used. Contact our parts department to select the filter for your conditions.

© Grindmaster Corporation, 1998
PRINTED IN U.S.A.

0306 FORM # AM-309-06
Part # 090-077

Prior authorization must be obtained from Grindmaster Corporation for all warranty claims.

Grindmaster Corporation

4003 Collins Lane
Louisville, KY 40245 USA
(502) 425-4776
(800) 695-4500 (USA & Canada only)
(800) 568-5715 (Technical Service Only)
FAX (502) 425-4664
www.grindmaster.com

WARNING

ELECTRIC SHOCK HAZARD!

Installation of this appliance should be performed by
qualified service personnel only. Improper installation could
result in electrocution.

Advertising
This manual is related to the following products: