Gardena WT1030 User Manual

Page 7

Advertising
background image

13

G

12

G

7. Putting Your Water Timer Out of Operation

v Please return flat batteries to a GARDENA dealer or dispose of

them properly at your nearest recycling centre.

Only dispose of batteries when they are flat.

v Store your Water Timer in a dry place away from frost before

the first frost sets in.

8. Technical Data

Min. / max. operating pressure :

1 bar / 12 bar

Flow medium :

Clean fresh water

Max. water temperature :

40 °C

Number of program-controlled watering cycles
per day:

Up to 3

Watering cycles per week :

Every day, every 2nd, 3rd or 7th day

Watering time per program :

1, 3, 5, 7, 10, 15, 20, 25, 30, 45, 60, 75, 90,
120, 150 or 180 minutes

Battery:

1 x 9 V alkali-manganese (alkaline)
type IEC 6LR61

Running time :

Approx. 1 year

Disposing of flat batteries :

Storage / Wintering :

6. Trouble-Shooting

Fault Possible

cause

Remedy

Not able to open the

Battery capacity too low

v Insert a new alkaline

Water Timer manually

(3 LED s flash).

battery.

using “ON / OFF”.

Tap turned off.

v Turn on tap.

Watering not initiated.

Control knob turned to

v Turn the control knob to

“Frequency” or “ON / OFF”.

“Run Time Minutes”.

Battery capacity too low

v Insert a new alkaline

3 LEDs flash).

battery.

Data input / changes made

v Input data or make changes

while the program was starting

before or after the starting

or immediately before.

times you have chosen.

Tap turned off.

v Turn on tap.

Battery flat after working

The battery you inserted

v Use an alkaline battery.

for a short time.

is not an alkaline battery.

If you have any other problems with your Water Timer, please contact GARDENA Service.