Installation instructions – Stovax RV76FK User Manual

Page 2

Advertising
background image

INSTALLATION INSTRUCTIONS

PR7587

1

Remove ash cover and hinges, diagram 1

Also see Riva MF Cassette Installation Instructions

(PM183) - Section 2. Ash pan door removal (Page

8)

PR7588

2

Remove fan fascias. Use the 2.5mm hex key

supplied. Keep left hand fascia, diagram 2

2

INSTALLATION INSTRUCTIONS

PACKING LIST

• Riva Fan Kit

TOOLS REQUIRED

• 2.5mm hex key supplied with Riva Cassette

POwER SUPPLy

A 230v 50 - 60Hz supply is required.

THIS APPLIANCE MUST BE EARTHED

Provision for the power supply should be made

before installing the product, with connections

made by a qualified electrician via a 3 Amp

supply and complying with any local and

national regulations and guidelines

If the electricity supply cable is damaged do not

use the appliance until it has been replaced. For

safety reasons the replacement should be carried

out by a Stovax servicing agent or a similarly

competent electrician.

Live

wire

Brown

Terminal Marked L / coloured

RED

Neutral

wire

Blue

Terminal Marked N / coloured

BLACK

Earth

wire

Green and

yellow stripes

Marked E /

/ colour GREEN

or GREEN & YELLOW

230v 50 - 60Hz supply is required

wARNING – FAILURE TO CONNECT THE

wIRES CORRECTLy COULD PUT PEOPLE AT

RISK FROM ELECTRIC SHOCK OR FIRE.

Advertising