Mounting Instructions

If the valve is plumbed with Port 2 as the common port and the main body of the

actuator is mounted over Port 2 (standard mounting), there is no need to adjust the

actuator cams.

1.

Remove Locking Knob and handle. Set aside for reinstallation later.

2.

Remove four (4) screws from the valve. Refer to Fig. 1 (mounting positions) to

determine which screws to remove.

3.

On the back side of the actuator, align the smallest slot on the actuator shaft with

the smallest slot on the valve diverter.

4.

With the two shafts engaged rotate the actuator until holes on the actuator align

with the screw holes on the cover.

5.

Use four (4) ¼-14x1½" long screws (packaged with the actuator) to secure it in

place. Do not overtighten - be careful if using a power screwdriver.

6.

Place valve handle on actuator shaft and tighten Locking Knob.

Cam Adjustment

1.

When changing the cam settings, move toggle switch at bottom of actuator to

the OFF (center) position.

2.

Unscrew and remove Locking Knob and handle from actuator shaft.

3.

Remove the four (4) screws which hold the actuator cover on and remove cover.

4.

The upper and lower cam are located on the actuator shaft. Slide the cams off the

shaft splines and rotate to the desired position. Refer to the charts on the

previous pages to determine the correct cam setting for your installation. Some

installations may require settings not found on the chart (partial open, partial

close, etc.) All settings are referenced from the small slot on the shaft, which is

always 12 o'clock (Fig. 2). The upper cam effects the clockwise position stop

point. The lower cam to effects the counterclockwise rotation stop point.

Fig. 2

12 o’clock

(small slot)

6 o’clock

3 o’clock

9 o’clock

Using the chart below to determine correct cam setting using standard clock posi-

tions. Refer to the "Cam Adjustment" section in this manual to change upper and

lower cam positions if necessary.

Two Port Valve

The Model GVA-24 Actuator may be mounted to the valve in four different positions.

In all cases, the cam settings are the same. Refer to the chart below for cam settings

for 2 way valves.

CAM SETTING

LOWER CAM

UPPER CAM

3 o'clock

6 o'clock

GVA

MOUNTING

OPTION

PORT

WHERE
WATER

ENTERS

CAM SETTING

PORT

WATER

WHERE
EXITS

LOWER CAM

UPPER CAM

PORT

PORT

1

6 o'clock

9 o'clock

2

3

A

2 (std)

12 o'clock

12 o'clock

1

3

(Standard)

3

3 o'clock

6 o'clock

1

2

1

9 o'clock

12 o'clock

2

3

B

2

3 o'clock

3 o'clock

1

3

3

6 o'clock

9 o'clock

1

2

1

3 o'clock

6 o'clock

2

3

C

2

9 o'clock

9 o'clock

1

3

3

12 o'clock

3 o'clock

1

2

1

12 o'clock

3 o'clock

2

3

D

2

6 o'clock

6 o'clock

1

3

3

9 o'clock

12 o'clock

1

2

4