Troubleshooting (cont.) – Global Machinery Company ATI2K User Manual

Page 13

Advertising
background image

13

Troubleshooting (cont.)

Trouble

Possible cause(s)

Suggested remedy(s)

Moisture blowing out of

tool.

1. Water in tank.

1. Drain tank. Oil tool and run until no

water is evident.

2. Water in air hoses.

2. a. Install a water filter.
b. Install an air dryer.

Impacts slowly or will not

impact.

1. Lack of lubrication.

1. Lubricate the air motor and impact

mechanism.

2. Tool regulator set in wrong position.

2. Adjust the regulator on the tool to

the maximum setting.

3. Inline regulator too low.

3. Adjust regulators in the air system.

Impacts rapidly but will

not remove bolts.

1. Worn impact mechanism.

1. a. Replace worn impact

mechanism components.
b. Return impact wrench for repair.

Does not impact.

1. Broken impact mechanism.

1. a. Replace broken impact

mechanism components.
b. Return impact wrench for repair.

Advertising