Ge is . . . sports lighting – GE UltraSport User Manual

Page 8

Advertising
background image

Lamp Specification—

The Ultra

Sport floodlight

takes advantage of metal halide lamp technology,
proven by decades of use in all types of lighting
application. It uses an advanced generation of lamps
specifically designed for use in sports lighting.
Offered in a choice of 2000, 1500 or 1000 watts, these
white
light sources feature a double-ended design
without an outer bulb, and provide an average rated
life of 3000, 6000 and 10,000 hours, respectively.

These advanced lamps also provide excellent color

rendering with a 4000 degree Kelvin color
temperature. They are designed for an orientation of
horizontal plus or minus 4 degrees, and have no tilt
factor.

Lamp Installation—

Ultra

Sport floodlights are

shipped with lamps installed.

The double-ended metal halide lamp mounts

transversely to a specific orientation by inserting the
lamp ends into pre-focussed ceramic holders. It is
held in place by stainless steel spring clips that snap/
lock in place. The electrical connection of the lamp is
separate from the mechanical support, and is made by
connecting the spade ended-lamp leads to the socket
terminals and tightening with a screwdriver.

8

GE is . . . Sports Lighting!

e

Metal Halide

Metal Halide

2000 Watt Double-Ended

1500 Watt Double-Ended

GE Lamp Number

MQI/2000/T9/40

MQI/1500/T8/40

Catalog Number—OSRAM Sylvania

M2000T9/DE

M1500/T9/DE

ANSI Designation

U134

U133

Burning Position

Horizontal ± 4 Degrees

Horizontal ± 4 Degrees

MOL

10.00 Inches (254mm)

10.00 Inches (254mm)

LCL

5.00 Inches (127mm)

5.00 Inches (127mm)

Arc Length

4.25 Inches (108mm)

4.25 Inches (108mm)

Base

Ceramic #10 Spade

Ceramic #8-10 Spade

Lamp Volts

250 ± 10 Volts

265 ± 10 Volts

Lamp Current

8.5 Amps

6.3 Amps

Ignitor Pulse (Peak)

4000-5000 Volts

4000-5000 Volts

Pulse Width @ 3600 volts

One Microsecond

One Microsecond

Minimum Pulse Required

4000 Volts

4000 Volts

Initial Lumens

200,000

160,000

Lumens at 100 Hours

100%

100%

Lumens at 40% Rated Life

85%

85%

Average Rated Life

3000 Hours

6000 Hours

Color Temperature

4000° Kelvin

4000° Kelvin

CRI

RA=65+

RA=65+

Hot Restart Capability

Yes

Yes

Lamp Seal Temperature

Not to exceed 450 degrees C.

Not to exceed 450 degrees C.

Bulb Wall Temperature

Not to exceed 950 degrees C.

Not to exceed 950 degrees C.

LAMP DATA