Global Machinery Company 2HP/1600W 32LT DUAL TANK COMPRESSOR WITH REMOVABLE TANK DTC32L User Manual

Page 12

Advertising
background image

12

4. Close the tank 1 isolation valve (18).

5. Disconnect the tank 1 inlet hose (25) from the combination

valve (8), by sliding back the sleeve of the quick connect

fitting and removing the inlet hose.

Note.

The inlet hose has been fitted with a special one way

valve. On removal of the inlet hose there will be a slight

discharge of air.
6. Place the tank 1 inlet hose

(25) on the provided clip.

7. Disconnect the rubber support

straps (22) by pulling them

over the support brackets (23)

to release the air tank.

WARNING.

Be careful when

releasing the straps they do have

a tight fit.
8. The tank has now been

correctly disconnected from the

air compressor unit. You can

now move the tank freely

by using the carry handle (20)

to lift and move the tank. You

can now use the removed tank.

The separated tank has two

outlets that you can choose

from;

a) the attached inflation hose; or

b) the provided quick connect coupler that you can connect

another air hose to. This can be done by sliding back

the sleeve of the quick connect coupler and inserting an

air hose assembly that is fitted with a Nikko style fittings.

Due to the limited supply of air it is recommended that

the removable tank is fully charged with air prior to being

removed.

Note.

While the tank has been

removed you can still use the

master unit/compressor with only

one tank. This can be done by

simply reconnecting the master

unit/compressor back to the power

supply, and turning the unit on at

the On/Off switch (2).

CAUTION.

When using the master unit/compressor with

the top tank removed always check to ensure that the air

isolation vale (18) is in the off position.

Installing the air tank:

1. Turn the On/Off switch (2) on the compressor to the

off position.

2. Turn the power supply off and disconnect the power cable.
3. Lift the main handle (1) up and away from the portable

tank location.

4. Sit the tank down on the

support brackets (23).

5. Reconnect the rubber support

straps (22) to the support

brackets (23).

Note.

Grip the rubber straps at

the fixed end and stretch evenly

over the tank until the straps are

connected securely to the support

brackets.

WARNING.

When extending the rubber straps be careful. If

released early they can flick back and hurt you. Make sure

that your face is at a safe distance from the rubber straps

while they are being stretched.

Advertising