Setup, Caution – Graco Inc. Hydra Clean 308532S User Manual

Page 5

Advertising
background image

308532

5

Setup

Check for Shipping Damage

Check the unit for any damage that may have occurred

in shipping. Notify the carrier immediately if there is

any damage.

Set Up

Charge the battery. Be sure the battery connections

are correct and secure. Connect the fuel line to the

engine using the quick coupler provided. Squeeze the

priming bulb 3 to 5 times. If you are using a down-

stream chemical injector, install it between the pump

unloader and the high pressure hose, using the quick

couplers provided.
Connect the high pressure hose between the pump

outlet and the gun inlet. Both of these connections are

made with quick couplers.

CAUTION

Up to 100 ft (30 m) of high pressure hose may

be used. Longer hoses may affect sprayer perform-

ance, and chemical injector performance, if used.

Install the appropriate spray tip on the wand. See

Installing and Changing Spray Tips. If you are using a

sandblaster kit, see its separate manual for installation

instructions.

Connect to Water Supply

CAUTION

Before attaching to the water supply, check your

local plumbing code regarding cross--connection to

the water supply. Use a backflow preventer if

required by local code.
Do not exceed 160_F (70_C) inlet water tempera-

ture.

Connect a hose with at least a 3/4 inch (19 mm) ID

from the water supply to the unit’s 3/4 inch garden

hose inlet. The supply hose should not be more than

50 ft (15 m) long.

NOTE: The water source at the unit must have a

minimum flow rate equal to that of the unit (see
Technical Data, inside back cover).