10. Electrical Load Information

The following charts

provide information for the electrician wiring the grain dryer and are a reference

guide for parts. You should contact the local power company and have a representative survey the
installation to see that the wiring is compatible with their system and that adequate power is supplied to
the unit. Remember that the only thing connected to the recommended service amps should be the
grain dryer.

Adhere to all electrical safety practices and codes. (Refer to the National Electrical Code Standard
handbook by the National Fire Protection Association). A qualified electrician must make all electrical
wiring installations.

Dryer

Model #

Voltage

Motor

HP

Fuel Load

Amps

Maximum Amps

with Auxiliaries

Minimum

Amps

Recommended

Service in Amps

Branch Breaker

in Amps

1108

1 PH 230V

Top Auger

1.5

8

153

62.5

200

60

Bottom Auger

1

6.5

60

Fan

10 to 12

48

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Top Auger

1.5

5

104

41.4

150

50

Bottom Auger

1

3.4

50

Fan

10 to 12

33

60

(2) Auxiliary

(2) 7.5

40

*

3 PH 440V

Top Auger

1.5

2.5

57

20.7

150

60

Bottom Auger

1

1.7

60

Fan

10 to 12

16.5

60

(2) Auxiliary

(2) 7.5

20

*

1110

1 PH 230V

Top Auger

2

14

162

70

225

60

Bottom Auger

1.5

8

60

Fan

10 to 12

48

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Top Auger

2

6.2

101

39.2

150

50

Bottom Auger

1.5

5

50

Fan

10

28

60

(2) Auxiliary

(2) 7.5

40

*

3 PH 440V

Top Auger

2

3.1

56

19.6

150

60

Bottom Auger

1.5

2.5

60

Fan

10

14

60

(2) Auxiliary

(2) 7.5

20

*

1112

1 PH 230V

Top Auger

2

14

196

100

300

60

Bottom Auger

1.5

8

60

Fan

10 to 17

78

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Top Auger

2

6.2

114

50.2

175

50

Bottom Auger

1.5

5

50

Fan

15

39

60

(2) Auxiliary

(2) 7.5

40

*

3 PH 440V

Top Auger

2

3.1

62

25.1

150

60

Bottom Auger

1.5

2.5

60

Fan

15

19.5

60

(2) Auxiliary

(2) 7.5

20

*

*Auxiliaries run through load and unload breakers.