EXHAUST LENGTH CALCULATION

WHEN INSTALLED IN MANUFACTURED

(MOBILE) HOMES -

USE OF CASTERS

(120V PORTABLE MODELS ONLY)

NOTE TO INSTALLER -

...AFTER INSTALLATION

CHECK THE FOLLOWING

ALCOVE OR CLOSET

INSTALLATION

Parts are available from your local service organization:

If your dryer is approved for installation in an alcove or closet, it will be stat-

ed on a label on the dryer back. The installation must conform to the follow-

ing specifications;

WARNING: TO PREVENT LARGE AMOUNTS OF LINT AND

MOISTURE FROM ACCUMULATING AND TO MAINTAIN DRYER

EFFICIENCY, THIS MACHINE MUST BE EXHAUSTED OUTDOORS.
Minimum clearances between dryer cabinet and adjacent walls or other

surfaces are:

NOTE: The clearances stated above are minimums. Consideration

must be given to the type accessory kit used with dryer. Refer to

the specific kit instruction for details.

Sides
Top
Front
Rear

Alcove Closet

0”
1”
-
3”

1”
1”
3“
3”

Closet doors must be louvered or otherwise ventilated and must contain

at least 60 square inches of area equally distributed. If this closet contains

both a washer and a dryer, doors must contain at least 120 square

inches of open area equally distributed.

EXHAUST DUCT - must meet specs on Page 3. No excessive turns.
No kinks or obstructions to air flow.
EXHAUST HOOD - should work freely and open downward.
GROUNDING - Dryer must be properly grounded to conform to local
codes and ordinance requirements.
OPERATION - turn dryer on and check for heat.
HAND CUSTOMER THE USE AND CARE BOOK - Give instructions
on operating the dryer - answer any questions.
GIVE THESE INSTALLATION INSTRUCTIONS to the customer.

Dryer must be exhausted to the outside. Exhaust MUST NOT be terminated

beneath mobile home. Exhaust material MUST NOT support combustion.

Installation MUST conform to Manufactured Home Construction & Safety

Standard, Title 24 CFR, Part 32-80 or when such standard is not applicable, the

American National Standard of Mobile Homes, ANSI/NFRA No. 501B-1977.

For electrical connection, see “Connecting dryer using 4 wire connection”.

For a portable installation screw casters into the holes on the bottom of the dryer. Refer to the “Installation Instructions for

caster assembly” sheet to install casters.

WX8X63 4”X1’ Duct

WX8X64 4”X2’ Duct

WX8X51 Elbow

WX8X59 Aluminum hood

RIGID (Preferred)

FLEXIBLE

4" DIA.

4"

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

14 m (46 ft)

11 m (38 ft)

9 m (31 ft)

7 m (24 ft)

0

1

2

3

11 m (37 ft)

9 m (30 ft)

6.5 m (22 ft)

4.5 m (15 ft)

Use only for short

run installations

CONNECTING THE DRYER

TO HOUSE VENT

Rigid metal transitions ducts reduce the risk of crush-

ing and kinking.

Never install flexible metal duct in walls, ceilings, floors

or other enclosed spaces.

For best drying performance, a rigid metal transition

duct is recommended.

Avoid resting the duct on sharp objects.

In Canada and the United States, only the flexible

metal(foil-type) ducts that comply with the “Outline for

Clothes Dryer Transition Duct Subject 2158A” shall be

used.

For many applications, installing elbows at both the

dryer and the wall is highly recommended (see illustra-

tions below). Elbows allow the dryer to sit close to the

wall without kinking and or crushing the transition

duct, maximizing drying performance.

Total length of flexible metal duct should not exceed 8

feet (2.4m).

RIGID METAL TRANSITION DUCT

If rigid metal duct cannot be used, then UL-listed

flexible metal (semi-rigid) ducting can be used (Kit

WX08X10077).

UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT

In special installations, it may be necessary to connect

the dryer to the house vent using a flexible metal (foil-

type) duct. A UL-listed flexible metal (foil-type)duct

may be used ONLY in installations where rigid metal or

flexible metal (semi-rigid) ducting cannot be used AND

where a 4" diameter can be maintained throughout the

entire length of the transition duct.

Never install flexible metal duct in walls, ceilings, floors

or other enclosed spaces.

Total length of flexible metal duct should not exceed 8

feet (2.4m).

Avoid resting the duct on sharp objects.

For best drying performance:

1. Slide one end of the duct over the clothes dryer outlet pipe.

2. Secure the duct with a clamp.

3. With the dryer in its permanent position, extend the

duct to its full length. Allow 2” of duct to overlap the

exhaust pipe. Cut off and remove excess duct. Keep

the duct as straight as possible for maximum airflow.

4. Secure the duct to the exhaust pipe with the other clamp.

UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT

Total length of flexible metal duct shall not exceed 8 ft (2.4 m).

The following kit is available from you local service organization:

Kit WX08X10077 - 4” dia. flexible metal (semi-rigid) UL-listed

transition duct (includes 2 elbows).

322B3166P001 pub # 31-16233