The installation space, Design guide, The installation space (cont.) – GE Monogram ZDWI240WII User Manual

Page 3

Advertising
background image

Design Guide

THE INSTALLATION SPACE

*For a standard installation of Custom-Framed unit: The

product must be installed so that the front face will project 2"
forward of adjacent cabinets. This position will allow a full door
swing and prevent interference with adjacent cabinetry. The
opening between cabinets must be 23-3/4" minimum.

*For a standard installation of Stainless Steel unit: The product

must be installed so that the front face will project 1-3/4"
forward of adjacent cabinets. This position will allow a full door
swing and prevent interference with adjacent cabinetry. The
opening between cabinets must be 23-3/4" minimum.

**For a flush installation of Stainless Steel unit: Install a

1/2"-wide filler strip on the hinge side. The filler strip will act as
a spacer between the door case and adjacent cabinets and will
prevent interference with the cabinet door swing. Recess the
filler strip 2" back from the front face of the unit, or even with
the front edge of the product case (behind the gasket). The width
of the opening must be 24-1/4" (including the 1/2" filler strip).

*** For a flush installation of Custom-Framed unit: Install a

1"-wide filler strip on the hinge side. The filler strip will act as
a spacer between the door case and adjacent cabinets and
will prevent interference with the cabinet door swing. Recess
the filler strip 2" back from the front face of the unit, or even with
the front edge of the product case (behind the gasket). The width
of the opening must be 24-3/4" (including the 1" filler strip).

• The wine chiller, wine reserve and beverage center can

be installed freestanding.

Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is required.

An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall
as shown. Electrical must be located on rear wall as shown.

NOTE: GFI (ground fault interrupter) is not recommended.

3

NOTE:

Handle and handle

standoff depth is 1-3/4"

THE INSTALLATION SPACE (cont.)

These products will fit flush to

adjacent cabinets when installed

with a Dim. A-width filler panel

or cleat. The filler panel should

be recessed or set back behind

the door and even with the front

edge of the product case.

Product

Dim. A

ZDWI240, ZDBI240

1"

ZDWC240, ZDWR240

1/2"

ZDBC240, ZDBR240

1/2"

In a standard installation,

the product will project forward

of adjacent cabinets. See Dim. A.

Flush

Installation

CABINET

CABINET

CABINET

CABINET

Dim. A

Dim. A

120°

120°

110°

110°

Filler panel or cleat

to be set back even

with front of case.

Front edge of product case

Front face

Front face

Front edge of product case

Standard

Installation

Product

Dim. A

ZDWI240, ZDBI240

2"

ZDWC240, ZDWR240

1-3/4"

ZDBC240, ZDBR240

1-3/4"