GTO UL325 SERIES User Manual

Page 38

Advertising
background image

35

Symptom

Diagnosis

Check

New installation that will not
work.

Power Problem

Dip Switch Settings

Transmitter

Antenna Receiver

•

Turn Power ON

•

Fuse

•

Battery Connections

•

Turn #5 dip switch OFF

•

Program the transmitter

•

Replace transmitter battery

•

Check Antenna Receiver Connections

Gate opens or closes too far
and blows the fuse.

Open or Closed position limit is not
programmed.

Gate Bracket is out of adjustment

•

Reset Limits

•

Adjust Gate Bracket with arm fully retracted.

Opener obstructs while
disconnected from the gate.

Stall Force Adjustment

Power Problem

Operator Arm Problem

•

Adjust Stall Force to Maximum

•

Battery Under Load

•

Test Rev Counter

Open and will not close

Power Problem

Shorted Accessory

•

Battery Under Load

•

Disconnect all hardwired accessories and try
the transmitter.

Hear warning buzzer and the
opener does not work.

One gate stops in the middle
of its cycle or operates
intermittently.

Operator arm won’t work or
works slowly or intermittently.

Power Problem

Bad Relay on PCB

Charging with Transformer:

•

Fuse Connection

•

Battery Under Load

•

Battery Connections

•

Charging Circuit

•

Transformer

Charging with Solar:

•

Weather

•

Solar Panel Placement

•

Battery Under Load

•

Charging Circuit

•

Solar Panel

Output of RED & BLK Master Input Terminals with
wires disconnected while pressing the transmitter.