Step-by-step instructions, Step-by-step instructions –12, Step-by-step installation instructions – GE GXSF39E User Manual

Page 6: Caution

Advertising
background image

6

Fig. 3A

Fig. 3B

Fig. 3C

IN

OUT

Turn bypass valve
upside down to
connect to floor
level plumbing

Valve body
inlet or outlet

Bypass valve
(push all the way in)

Clip

END
VIEW

Clip

Outlet

Inlet

O-ring seal goes into
the outer groove only.
The clip snaps into the
inner groove (see below).

Bypass
valve

SIDE
VIEW

Step-by-step installation instructions.

Turn off the gas or electric supply to the water heater, in the possibility
that the water heater may be drained while draining pipes.

Turn off the water supply to pipes to be cut and drain the house
water pipes.

Open both hot and cold faucets at the lowest location possible.
Release 2 clips at rear of cover. Rotate cover forward and lift up.

NOTE: For easier installation, remove the top cover.

1. INSTALL BYPASS VALVE

Remove plastic shipping plug and wire from valve outlet.

Push the bypass valve (lubricate o-ring seals with silicone grease)

into both ports of the valve as shown in Fig. 3A.

Snap the 2 large plastic clips in place, from the top, down as shown

in Figures 3A and 3B. Be sure they snap into place. Pull on the
bypass valve to make sure it is held securely in place.

2. MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION

Be sure the installation surface is level and smooth. Sharp objects
under the tank may puncture it. If needed, place the tank on a section
of 3/4

″ thick (minimum) plywood. Then, place shims under the

plywood as needed to level the softener.

3. PLUMB “IN” AND “OUT” PIPES TO AND FROM SOFTENER

CAUTION:

Observe all of the following cautions as you

connect inlet and outlet plumbing. See illustrations on page 5.

BE SURE INCOMING HARD WATER SUPPLY IS DIRECTED TO THE

SOFTENER VALVE INLET PORT. If house water flow is from the left,
use a plumbing crossover as shown in Fig. 1, page 5. If the house water
flows up from the floor level, turn the bypass valve upside down as shown
in Fig. 3C.

If making a soldered copper installation, do all sweat soldering before

connecting pipes to the bypass valve.

Torch heat will damage plastic

parts.

When turning threaded pipe fittings onto plastic fittings, use care not

to cross-thread.

Use pipe joint compound on all external pipe threads.

Support inlet and outlet plumbing in some manner (use pipe hangers)

to keep the weight off of the valve fittings.

NOTE: Be sure the turbine and
support are firmly in place in the
valve outlet. Blow into the valve
port and observe the turbine
for free rotation.

Turbine

Valve outlet

Turbine shaft
and support

Drain Fitting

Advertising