SR/SC Series "A" Woodburning Fireplace

7412948

Continue installing the pipe as required until pipe is
installed up through the ceiling. At this point, you must
install a firestop spacer.

Installing the Firestop Spacer

in the Ceiling Hole

A firestop spacer is used to keep pipe spaced properly
and required for safety.

Nail the firestop spacer (at each corner) to the framing
members of the ceiling hole. NOTE: A firestop spacer
is not required at the roof.

Hole sizes listed in Figure 13 for angled firestop
spacers provide minimum required air space to chim-
ney pipe for ceiling thickness up to 8" (203mm). When
combined thickness of ceiling material, ceiling joists
and flooring material exceeds 8" (203mm), adjustments
must be made in framing to assure that minimum air
spaces to chimney are maintained.

Proper Firestop Spacer Installation

Figure 18 shows different installation procedures for
both an area that

is an attic and an area that is not an

attic.

If the area above the ceiling is not an attic, position the
firestop spacer with the flange on the ceiling side and
the angled portion extending up into the hole.

If the area above the ceiling is an attic, position the
firestop spacer with the flange on the top of the framed
hole and the angled portion extending down into the
hole.

Firestop spacers are not available for nor are they
required on vertical walls.

DO NOT put any sealant around the area where the
outer pipe slides through the firestop spacer. If you
seal this area, it may cause a fire hazard.

Canadian Requirements

for Insulation Shield

In Canada, an attic
insulation shield is
required to prevent attic
insulation from contact-
ing the chimney sec-
tion. Framing dimen-
sions for the chimney
hole should measure
14

¹⁄₂

" x 14

¹⁄₂

" (368 x

368mm). An attic shield
MUST be installed on
top of attic joists (above
the floor level). (Fig.
19)

UP

FP558

Fig. 16 Install pipe, listening for the snap-lock to fasten.

Pipe Section

Pipe
Rim

Hem

Pipe
Rim

Lance

Elbow Strap

Angled Strap

Fig. 17 Attach straps to a structural framing member.

FP270/271

Support Structure

Elbow Strap
(must be tight)

Ceiling Hole
Framing

Angle Firestop

Chimney Support Strap
(must be tight)

Fig. 18 Installing firestop spacer.

FP593

Attic Installation

Ceiling Installation

Nails (4)

Firestop
Spacer

Joist

Joist

Firestop
Spacer

Nails (4)