Site considerations, Maintenance – Milan Technology HB-E-TX-8 User Manual

Page 7

Advertising
background image

LAN Master™ TX8

4

11

100BASE-TX 8-Port Hub

2. SITE CONSIDERATIONS

The site for the LAN Master™ TX8 hub must provide:

•

AC power outlet for each hub

•

Adequate ventilation

•

Standard environmental conditions

•

Isolation from electrical noise, including radio transmitters
and broadband amplifiers, motors, high power electrical
lines, or fluorescent light fixtures.

Additionally:

•

The twisted pair cables should not run in the same conduit
with power line cables

•

Phone lines should be separated from data cables

•

Flat or “silver satin” wires should not be used.

And:

•

Since the LAN Master™ TX8 functions as an Ethernet
Repeater, the entire installation should comply with the IEEE
Ethernet 802.3 specification.

5. MAINTENANCE

WARNING: DO NOT, UNDER ANY CIRCUMSTANCES,
open and attempt to repair the LAN Master™ TX8
100BASE-TX 8-Port Hub. Failure to observe this warning
could result in personal injury or death from electrical
shock.

NOTE: Failure to observe the above warning will immediately void
the warranty.

Fault Isolation

If two network devices fail to communicate through the LAN
Master™ TX8, consider the following:

•

Are the LEDs described in the previous section functioning
properly?

•

Do network devices have Link Integrity enabled?

•

Do network devices communicate when the LAN Master™
TX8 is not installed between them?

•

Is flat or “silver satin” wire used in site internal wiring?

•

Are internal wiring patch cords, punch down blocks, and
wall jacks properly pinned or configured?

•

Are network interface cards properly configured?

Technical Support Contact

For assistance in fault isolation and in maintaining the LAN
Master™ TX8 100BASE-TX 8-Port Hub, contact:

Technical Support

(800) 260-1312

or your local distributor.

Advertising