CHAPTER 2: POWER REQUIREMENTS

16

V pk (drop) = I pk x R (cable total)

The Burst Current can also be used to calculate the AC
looping capability of MINA.

■

Ultimate Short-Term Peak Current — A rating for fast-
reacting magnetic breakers.

■

Inrush Current — The spike of initial current encoun-
tered when powering on.

You can use the following table as a guide for selecting
cable gauges and circuit breaker ratings for the system’s
operating voltage.

The minimum electrical service amperage required by a
MINA loudspeaker system is the sum of the Maximum Long-
Term Continuous Current for each loudspeaker. An addi-
tional 30 percent above the minimum amperage is recom-
mended to prevent peak voltage drops at the service entry.

NOTE:

For best performance, the AC cable

voltage drop should not exceed 10 V, or

10 percent at 115 V and 5 percent at 230 V. Make
sure that even with AC voltage drops that the AC
voltage always remains within the operating win-
dows.

ELECTRICAL SAFETY ISSUES

Pay close attention to these important electrical and safety
issues.

■

MINA requires a grounded outlet. Always use a
grounded outlet and plug.

■

Do not use a ground-lifting adapter or cut the AC cable
ground pin.

■

Do not exceed the current capability of the 20-amp AC
Input connector for the loudspeaker. When looping loud-
speakers, consider the total current draw for all loud-
speakers on the circuit, including the first loudspeaker.

■

Make sure the AC power cable for the loudspeaker has
the appropriate power plug (on the other end) for the
area in which you will operate the loudspeaker. In addi-
tion, the AC power cable must be rated for the total cur-
rent draw of all loudspeakers looped from the power
source.

■

Do not operate the unit if its power cable is frayed or bro-
ken.

■

Keep all liquids away from MINA to avoid hazards from
electrical shock.

MINA Current Draw

Current Draw

115 V AC

230 V AC

100 V AC

Idle Current

0.256 A rms

0.249 A rms

0.284 A rms

Maximum Long-Term
Continuous Current

1.26 A rms

0.66 A rms

1.50 A rms

Burst Current

3.24 A rms

1.74 A rms

4.02 A rms

Ultimate Short-Term
Peak Current

10.4 A peak

5.2 A peak

11.1 A peak

Inrush Current

16.8 A peak

20.0 A peak

15.0 A peak

Earth ground

Chassis ground