Appendix A: Troubleshooting

Diagnosing Switch Indicators

Diagnosing Power Problems with the LEDs

The Power and RPS LEDs work in combination to indicate power status as follows.

Table A-1 Troubleshooting Chart

Symptom

Action

PWR LED is Off

• Check connections between the switch, the power cord and the wall

outlet.

• Contact your dealer for assistance

PWR LED is Amber

• Internal power supply has failed. Contact your local dealer for

assistance.

Diag LED is Amber

• Power cycle the switch to try and clear the condition
• If the condition does not clear, contact your dealer for assistance

Stack Master LED is Flashing

Amber

• The stack has not completed its initial configuration. Wait a few

minutes for the process to complete.

• If flashing continues, check that the Master Select button is pressed in

on only one switch.

• Check that all stacking cables are properly connected.

Link LED is Off

• Verify that the switch and attached device are powered on.
• Be sure the cable is plugged into both the switch and corresponding

device.

• If the switch is installed in a rack, check the connections to the

punch-down block and patch panel.

• Verify that the proper cable type is used and its length does not exceed

specified limits.

• Check the adapter on the attached device and cable connections for

possible defects. Replace the defective adapter or cable if necessary.

Table A-2 Power/RPS LEDs

Power LED

RPS LED

Status

Green

Amber

Internal power functioning normally; RPS plugged in.

Green

Off

Internal power functioning normally; RPS not plugged in.

Amber

Green

Internal power faulty; RPS delivering power.

Off

Off

Both internal power and RPS unplugged or not functioning.