2 MAINTENANCE

PROCEDURES

2-4

RAM CONTROL TIMER ADJUSTMENT

Determine the cycle time of your machine. This can be found in the “CHARTS” section
of this manual under “TIMER SETTINGS”. Set the timers as shown in the chart.
When the switches are properly set, the ram will fully extend, stop for one-half to one
second, then fully retract, stop and the unit will shut down.
NOTE: As time passes, the cycle time may change and need to be readjusted.
To set a timer, move the appropriate binary switches to the ON position. The timer
switch settings are cumulative (all switches in the ON position add up to the total num-
ber of seconds for the timer setting).

Ex. :

Switch 1 ( 1 sec)

= OFF

Switch 2 ( 2 sec)

= OFF

Switch 3 ( 4 sec)

= ON

4 sec

Switch 4 ( 8 sec)

= ON

8 sec

Switch 5 ( 16 sec) = ON

16 sec

Switch 6 ( 32 sec) = OFF
Switch 7 ( 64 sec) = OFF
Switch 8 (128 sec) = OFF
Switch 9 (256 sec) = OFF
Switch 10 (512 sec) = OFF
Timer Setting

=

28 sec