Motorola WSM6300 User Manual

Page 14

Advertising
background image

Parameter

Description

Parity

Refers to the bit that is used for error checking.

Stop

Refers to the number of bits used as stop bits.

GPIO

General Purpose Input / Output. Can be set to output to
control external logic controllable devices. Can be set to an
input to monitor an external logic level. Voltage on this pin
should must remain within 0.0 to 4.0 volts!!
The GPIO
must be set to RS 485 transmit enable when the WSM6300 is
configured for use with a RS 485 interface.

RS-485 Transmit Enable

Used when the device is manually configured to support RS-
485.

Transmission Event Type

Parameter used to define how often or when derail data is
packetized and sent to a destination via the wireless network.
Three choices exist as follows:

Update Interval – Data is packetized for transmission at

this periodic interval.

Sync

Character

- Data is packetized for transmission when

this ASCII character is received from the serial

interface.

Bytes

Collected - Data is packetized for transmission when

this number of bytes is collected in the serial interface

receive

buffer.

Transmit IP Address

IP Address that a sensor to will send its data to. This address
can be on the same host that executes MeshManager or a
standalone host. Each sensor node can be configured to send
data to a different host, i.e., – all temperature sensors would
report data to one host address and all fluid level sensors
would report data to another host address. This address must
be on the same segment of the network as the MeshManager.
This is achieved by attaching a host to one of the available
LAN ports on the CyberGuard SG300. The destination host
will typically use the Sensor API to transfer data to a sensor
management application. This field must be populated to
enable the serial port.

8