Master out/slave in, Subwoofer bypass foot switch, Remote indicator – MACKIE HRS120 User Manual

Page 10

Advertising
background image

10

Frequencies below the crossover frequency

are sent to the subwoofer, and frequencies
above the crossover frequency are sent to the
LEFT and RIGHT OUTputs, which are con-
nected to the main/satellite speakers.

Set the crossover frequency to the lowest

frequency response rating of the main/satellite
speakers.

MASTER OUT/SLAVE IN

Balanced XLR and unbalanced RCA female

connectors are provided for the

MASTER OUT/

SLAVE INputs. Use these for daisy-chaining two
HRS120s by connecting the

MASTER OUT jack

from the first subwoofer to the

SLAVE IN jack

on the second subwoofer (see note below).

The

SLAVE IN bypasses all filtering, but is

affected by the

POLARITY and INPUT SENSI-

TIVITY settings.

The

MASTER OUT is post-filtering (variable

and elliptical crossover, subsonic filter, and
LFE gain) and pre-

POLARITY and INPUT

SENSITIVITY.

Note: You cannot daisy-chain more than one

additional subwoofer using these connections.
If

SLAVE IN is used as an input, the MASTER

OUT has no signal present. To connect more
subwoofers, connect the

MASTER OUT from

the first subwoofer to the

LEFT (MONO) INput

of the second subwoofer with the

FILTER BY-

PASS switch pushed in. Then connect the
MASTER OUT of the second subwoofer to the
LEFT (MONO) INput of the third subwoofer,
and so on.

SUBWOOFER BYPASS FOOT SWITCH

This is a 1/4" jack for connecting a normally-

open footswitch. When the switch is closed, the
subwoofer is muted and the

LEFT and RIGHT

OUTputs pass the full-range signal to the
main/satellite speakers.

This is useful for making a quick compari-

son between the HRS120 enhanced and
non-enhanced low-frequency playback.

REMOTE INDICATOR

This is a 1/4" jack for connecting a remote

indicator to indicate when the subwoofer is by-
passed. An internal relay closes, shorting the
tip and sleeve of the

REMOTE INDICATOR

jack whenever the subwoofer is in bypass
mode, either triggered manually with the
FOOT SWITCH or by the auto-off function.

This can be used to turn on a remote, low-

voltage lamp. Note that this jack does not
provide power. It accepts a maximum of 24 VDC

S

M

SLAVE/MASTER

SLAVE

IN

MASTER

OUT

LEFT

IN

OUT

RIGHT

IN

OUT

FOOT SWITCH

*MAX OPEN CIRCUIT 24V

*MAX CLOSED CIRCUIT 1A

OPEN - SUB ON, L/R BASS MANAGED

CLOSED - SUB DEFEAT, L/R FULL RANGE

REMOTE INDICATOR

CROSSOVER

SUB

110Hz

55Hz

80Hz

SAT

CROSSOVER

SUB

110Hz

55Hz

80Hz

SAT

(MONO)

OUT

IN

L

R

L

R

SUBWOOFER BYPASS

POLARITY &

INPUT SENSITIVITY ACTIVE

PROCESSED SIGNAL

120 VAC, 60 Hz,

575 WATTS

POWER

ON

across the tip/sleeve when the internal relay is
open, and a maximum 1 amp of current when
the relay is closed.

CAUTION: There is an in-
ternal 1A fuse to protect the
REMOTE INDICATOR circuit.
Exceeding 1A of current may
blow the internal 1A fuse.

Advertising