page 10 —ST2010 SerieS SubmerSible pump • operaTion and parTS manual — rev. #3 (12/07/12)

general infOrMatiOn

inTroduCTion

The Multiquip Model ST-2010 submersible pump is

designed to pump water and is used for the draining (de-

watering) of well casings construction sites, cofferdams,

manholes, transformer vaults and excavations. The ST-

2010TCUL is designed for heavily debris-laden water and

the 2-inch discharge port can handle solids up to one inch

in diameter.
A cast ductile iron type impeller is attached to the output

shaft of a 1 HP electric motor which provides adequate

power for general purpose pumping. This submersible

pump is supplied complete with an electric power cable,

and a discharge port which accepts a 2-inch hose.
This pump is ideal for portability because of its light

weight and carrying handle. For reliability and long life, a

mechanical seal provides shaft sealing, with an oil chamber

separating the pump section from the motor.
The pump when in use, should be installed as free standing

(upright position) on its strainer base. A 2-inch discharge

hose (not supplied) should be connected to the discharge

port. The discharge hose should be adequately supported

to avoid stress on the pump.
For maximum water flow, the discharge hose should be

kept as short as possible, and with minimum elevation

above the pump. Remember as the length and/or height

of the discharge hose is increased, the flow of water will

be reduced. Also any reduction in the hose size, and any

fittings such as valves or outlet nozzles, will restrict the

water flow.
To avoid back-siphonage when the pump is switched off,

ensure that the end of the discharge hose is installed above

the water level at the final discharge point.
When the pump is switched off, the water remaining in the

hose will run back through the pump. This can be avoided

by placing a non-return valve in the hose nearest the pump.
never use this submersible pump to pump flammable

liquids or operate in a explosive or flammable environment.
Avoid using this pump in conditions where mud, grit, silt

or other debris are present. These conditions could cause

blockage and cause excessive pump wear.
do noT install the pump directly into an area where there

is a heavy build-up of mud, grit, silt or debris. If this condition

is present, install the pump on a platform before operating.

This pump must always be positioned on a platform in an

upright position.

never operate the pump by a suspended

rope. To prevent large solids from entering the pump, install

a wire mesh screen or similar barrier around the pump.
If the pump was used to pump water containing mud, silt,

use clean water to flush out the pump after each use.
do noT allow the pump to run dry, as this will damage the

pump. During maintenance, dry running is permissible but

only for a few seconds.
never lift the pump by its electrical power cord. alWaYS

lift the pump by its carrying handle or attach a rope to the

carrying handle.
A pump fully submerged in liquid will not freeze, unless

the liquid freezes.

do noT allow a partially submerged

pump to freeze. The expansion of water freezing in the

volute may crack the pump, causing expensive repairs. If

there is any danger of the pump being subjected to freezing

temperatures, Lift the pump from water and allow it to drain

thoroughly.
If the pump jams or the pump rotor locks for any reason,

disconnect the pump from the power source immediately.

Allowing the pump motor to cycle ON and OFF under an

overload condition can burn out the motor.
When replacement of nuts and bolts is required, use only

recommended parts as referenced in the parts section of

this manual. This pump uses metric threads.

do noT use

English measurement threads.

Failure to follow the above referenced precautions could

result in serious injury or death! Replace pump cord

immediately if cord becomes damaged or severed. This

pump must be installed in accordance with National Electric

Code ANSI/NFPA 70 so as to prevent moisture from

entering or accumulating with the boxes, conduit bodies

fittings, float housing or cable.

Warning

Explosion or Fire Hazard exists if this

pump is used with flammable liquids.

do

noT use this pump with flammable liquids.

do noT install this pump in hazardous

locations as defined by the National

Electrical Code, ANSI/NFPA 70.