Supporting burner air and gas piping, Burner mounting flange loads, Storage of inditherm® burners – Maxon Telecom INDITHERM 300 User Manual

Page 12: Handling of inditherm® burners, Orientation of inditherm® burners, Burner mounting, Installation and operation instructions for, Burners, Inditherm, Application requirements

Advertising
background image

Low temperature burners - INDITHERM

®

w w w . m a x o n c o r p . c o m

combustion systems for industry

MAXON reserves the right to alter specifications and data without prior notice.
© 2008 Copyright Maxon Corporation. All rights reserved.

1 - 2.3 - 17
E - m - 7/08

Installation and operation instructions for

INDITHERM

®

burners

Application requirements

Supporting burner air and gas piping

The INDITHERM

®

burner shall not be used as support for the piping to the burner. Gas and air piping shall be supported in such a

way that no additional loads will be created on the burner.

Burner mounting flange loads

Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to support the
complete burner weight.

Installation instructions

Storage of INDITHERM

®

burners

INDITHERM

®

burners shall be stored dry (inside). Burner blocks have been cured carefully before shipment and shall be kept dry.

Wetting of the blocks could result in premature failures.

Handling of INDITHERM

®

burners

INDITHERM

®

burners are shipped as complete units. Handle burners with care, using proper equipment during unpacking,

transport, lifting and installation. Any impact on the burner could result in damage. To prevent damage in transit, accessories such
as flame rods, control valves, UV-scanners, may be packed separately and shipped loose.

Orientation of INDITHERM

®

burners

INDITHERM

®

burners can be mounted and fired in any direction. However we advise to avoid orientations which can permit flame

supervision ports to collect debris and/or moisture. Also check limitations on orientation of other components mounted on the
burner head.

Burner mounting

Bolt the burner to the installation’s burner mounting flange. Use proper gaskets between burner and burner mounting flange
(option available).Tighten the flange bolting with correct torque. Retighten all bolts after first firing and regularly after
commissioning.