41 electrical schematics – Moyer Diebel 401-HTN User Manual

Page 47

Advertising
background image

41

ELECTRICAL SCHEMATICS

BLK

BLACK

BLU

BLUE

CAM 1 HOMING
CAM 2 PUMP MOTOR
CAM 3 PUMP MOTOR REVERSING
CAM 4 DRAIN
CAM 5 FILL
CAM 6 RINSE
CAM 7 SANITIZER
CAM 8 DETERGENT
CAM 9 CYCLE

CLT

CYCLE ON LIGHT

DM

DETERGENT MOTOR

DP

DRAIN PUMP (IF USED)

RL

RELAY

DV

DRAIN VALVE

FV

FILL VALVE

GND GROUND
GRN GREEN
HTLS HIGH LIMIT THERMOSTAT
MSW MAIN SWITCH ON/FILL OFF/DRAIN
PSDR PRIME SWITCH DETERGENT, RINSE

CUSTOMER TO SUPPLY RATED
VOLTAGE/PHASE/Hz, AS SPECIFIED
PER ORDER, TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION
POINT MUST COMPLY WITH ALL LOCAL
ELECTRICAL CODES.

00044

PSS

PRIME SWITCH SANITIZER

ICR

RELAY

DSS

REED SWITCH

RM

RINSE MOTOR (IF USED)

SRC

CURRENT OPERATED START RELAY COIL

SM

SANITIZER MOTOR

TM

TIMER MOTOR

TP

THERMAL PROTECTOR

WHT WHITE
WHTR WATER HEATER
WTS

WATER THERMOSTAT

Figure 13 — Electrical Diagram, 401-HTN

Advertising
This manual is related to the following products: