Uvsrc vent-free fireboxes, Installing the firebox – Majestic Appliances UVSRC36A User Manual

Page 5

Advertising
background image

5

UVSRC Vent-Free Fireboxes

20007435

opening and a 10” projection at 24” above the
opening. (Fig. 3b and 3c)

To install the optional canopy, you will need a
phillips screwdriver. The canopy has four holes
along the top edge. The middle two holes are
smaller than the outer two holes. Remove the
four (4) screws in the upper channel (to front
edge) of the firebox. The canopy will fit tightly in
the top front edge of the fireplace opening. Attach
the canopy with the four (4) sheet metal screws
previously removed from the upper channel.

4. Floor Clearances: No clearance is required if the

appliance is installed per these instructions.

Installing the Firebox

This list of specific instructions will help you make
certain that every installation operation is done cor-
rectly. Complete the installation steps in the sequence
shown.

LOCAL BUILDING CODES SHOULD BE CONSULTED
IN ALL CASES AS TO THE PARTICULAR REQUIRE-
MENTS CONCERNING THE INSTALLATION OF
FACTORY BUILT FIREPLACES.

Select the location for the fireplace by taking into
consideration the factors previously outlined in the
Choosing the Location section of the manual.

Step 1: Framing the Firebox

The width of the framed opening must be 39

¹⁄₄

" for

UVSRC36A or 45

¹⁄₄

" for UVSRC42A. (Fig. 4)

The entire fireplace can be elevated above the floor to
achieve a raised hearth effect. This can be done by
adding a small platform to achieve the desired height.

NOTE: See pre-wiring of Junction Box and Electrical
Services on Page 7.

Step 2: Install the Firebox

Install the firebox into the framed opening by setting it
directly in front of the opening and sliding it into the
proper position.

Step 3: Level the Firebox

Check the level of the firebox on the top edge of the
fireplace face. Shim if necessary.

Step 4: Secure the Firebox

Secure the fireplace to the framing. The nailing flanges
on the firebox will make securing the firebox to the
frame quick and easy. Use appropriate size nails or
screws to secure the firebox.

Step 5: Gas Piping and Connection

The gas piping must be installed in accordance with
local codes or, in the absence of local codes, in accor-
dance with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, latest edition.

8

10

12

14

16

18

20

22

24

2

4

6

8

10

8

10

12

14

16

18

20

22

2

4

6

8

10

6

42"

5" Min.

9

¹⁄₂

"

Min.

24"

Min.

10"

6"

16"

Min.

Combustible
Perpendicular Wall

3a

Noncombustible
Material

Fireplace
Opening

FP604a

Clearances
without Canopy

3b

3c

Clearance* from

T

op of Fireplace Opening (“)

Mantel (Combustible)
Projections (“)

Clearance to Combustible Mantel
Projections without Canopy

T225

Fig. 3 Clearances to combustibles.

*Combustible projections above
the fireplace must be within the
area described by the dashed line.

Clearance* from

T

op of Fireplace Opening (“)

Mantel (Combustible)
Projections (“)

3d

Clearance to Combustible Mantel
Projections with Canopy