Multi-Tech Systems MT2834ZDX User Manual

Page 11

Advertising
background image

Chapter 3 – AT Commands, S-Registers, and Results Codes

Multi-Tech Systems, Inc. MT2834ZDX User's Guide

11



Command:

$En V.42 Error Correction at 300 bps

Values:

n = 0 or 1

Default:

0

Description:

$E0 V.42 error correction at 300 bps disabled.

$E1 V.42 error correction at 300 bps enabled.


Command:

$EBn Asynchronous Word Length

Values:

n = 0 or 1

Default:

0

Description:

$EB0 10-bit mode enabled.

$EB1 11-bit mode enabled.


Command:

%En Escape Sequence Options

Values:

n = 0–5

Defaults:

1 and 4

Description:

%E0 Modem won’t escape.

%E1

+++AT<CR> method.

%E2

<BREAK>AT<CR> method.

%E3

Both

+++AT<CR> and <BREAK>AT<CR> methods.

%E4 No OK response to +++AT<CR>.

%E5 OK response to +++AT<CR>.


Command:

&Fn Load Default Configurations

Values:

n = 0, 8, or 9

Default:

8

Description:

&F0 Load factory default values from ROM if &F8 was previously stored; load user default values
from non-volatile memory if &F9 was previously stored.

&F8 Read factory default values when &F is issued (effective only if you store &F8 using &W0).

&F9 Read values stored in non-volatile memory when &F is issued (effective only if you store &F9
using &W0).


Command:

$Fn Enable/Disable Auto-Reliable Fallback Character

Values:

n = 0 or 1

Default:

0

Description:

$F0 Do not fall back to non-error correction mode connect if <CR> is received during handshake.

$F1 Fall back to non-error correction mode connect if <CR> is received during handshake.


Command:

%Fn Echo Frequency Canceller Offset Compensation

Values:

n = 0 or 1

Default:

0

Description:

%F0 Disable echo canceller frequency offset compensation.

%F1 Enable echo canceller frequency offset compensation.


Command:

#Fn Fallback Modes When Online

Values:

n = 0, 1, or 2

Default:

2

Description:

#F0 No fallback when on line.

#F1 Fallback decrementally from maximum speed to 4800 bps as line conditions deteriorate.

#F2 Fallback decrementally to 4800 bps; fall forward when line conditions improve.


Command:

&Gn Guard Tones

Values:

n = 0, 1, or 2

Default:

0

Description:

&G0 Turn off ITU-T guard tones.

&G1 Turn on ITU-T 550 Hz guard tone.

&G2 Turn on ITU-T 1800 Hz guard tone.

Note:

The ZDXK is locked to the ITU-T 1800 Hz guard tone (&G2).


Command:

Hn On Hook/Off Hook

Values:

n = 0 or 1

Default:

None

Description:

H0 Go on hook (hang up).

H1 Go off hook.