Installation instructions – Miele KM84-2 User Manual

Page 22

Advertising
background image

Installation instructions

There must be a minimum distance of 1-
3/16" (30 mm) between the cooktop
and adjacent cabinet or tall appliance.

Prepare the countertop cut-out as il-
lustrated.
Dimension ”B“ will change depend-
ing on how many combisets are
installed and is given on the chart.

Depth

in

mm *

Width

(Dimen-

sion B)

in mm

Width

(Dimensio

n B) in

inches

2 zone Combiset

1 appliance
2 appliances
3 appliances
4 appliances
5 appliances

490
490
490
490
490

265
558
851

1144
1437

10-7/16"

22"

33-1/2"

45-1/16"

56-5/8"

4 zone Combiset

1 appliance
2 appliances
3 appliances

490
490
490

560

1143
1728

22-1/16"

45"

68-1/16"

Combination

One 2 zone
+ one 4 zone

Two 2 zone
+ one 4 zone

Three 2 zone
+ one 4 zone

One 2 zone
+ two 4 zone

Two 2 zone
+ two 4 zone

490

490

490

490

490

851

1143

1437

1436

1729

33-1/2"

45"

56-5/8"

56-9/16"

68-1/16"

Extractor (e.g. DA 8-2)

For installation between two appliances:
-

Dimension

B

increases by 90 mm (3 9/16").

For installation at the end of a combination:
-

Dimension

B

increases by 98 mm (3 7/8").

* 490 mm = 19 5/16 "