Lighting pilot for the first time, Lighting pilot, Pilot – Monessen Hearth CSDV40SLP User Manual

Page 30

Advertising
background image

30

58D6056

CSDV Series Direct Vent Gas Stove

OpERATING INSTRUCTIONS

LIGHTING pILOT FOR THE FIRST TImE

W

ARNING

Never use an open flame to check
for gas leaks.

INITIAL LIGHTING
Purge air from the supply line as follows:

• Open main shutoff valve.
• Unscrew main pressure test point.
• Leave inlet test screw open until gas

comes in.

• When gas is flowing, tighten inlet screw

immediately.

W

ARNING

If using a soap and water solutiong
to test for leaks, DO NOT spray
solution onto control body.

LEAK TESTING
You may check for gas leaks with the following
methods only:

• Soap and water solution
• An approved leak testing spray
• Electronic sniffer

Check for gas leaks in each of the following locations:

• Pipe from the gas supply line connection to the gas valve
• Burner connections

• Field made joints / gas shutoff valve

• Pilot

• Factory made joints

• Each joint or connection

• All joints on valve and control body

1. Depress and turn knob counterclockwise

to pilot position.

2. Depress fully and hold pilot gas knob. The

electronic ignitor will automatically ignite the
pilot. Keep knob fully depressed for a few sec-
onds. Release and check that pilot continues
to burn.

If the pilot does not stay lit, repeat Steps 1 and 2.

Figure 42 -
Pilot Position

LIGHTING pILOT

PILOT

OF

   

   

 P

IL

O

    ON

FP1935
control knob pilot

The control has an interlock device that does not allow the lighting of the
stove up to the moment the safety device of the flame has not interrupted
the gas flow. After that period of time (when the magnet is closed), it is
possible to start the lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use
any tools during this operation. Damaged knobs may result in serious
injury.

W

ARNING

Advertising