3. Network Functions

3.8.2 Communication setup

3.8.3 Communication port

1) Using the COMMUNICATION TYPE menu, select the NETWORK BRIDGE

for the CONTROL port.

2) Using the SERIAL SETTINGS menu, select the proper baud rate and parity

for the CONTROL port, according to the specification of the RS-232C port of the
connected device.

For the NETWORK BRIDGE function, send the data from the computer to the
projector with using the Network Bridge Port that is configured in the “Port
Settings” of web browser. (

18)

3) Using the TRANSMISSION METHOD menu, set up the proper method for the

CONTROL port according to your use.

• The OFF is selected for the COMMUNICATION TYPE as the default

setting.
• Using the COMMUNICATION menu, set up the communication. Remember
that an unsuitable setup could cause malfunction of communication.
• When COMMUNICATION TYPE is set to NETWORK BRIDGE, the CONTROL
port doesn't accept RS-232C commands.

• Except for 9715, 9716, 9719, 4352 between 1024 and 65535 can be

set up as the Network Bridge Port number. It is set to 9717 as the default
setting.

NOTE

NOTE

Item

Condition

BAUD RATE

4800bps/9600bps/19200bps/38400bps

PARITY

NONE/ODD/EVEN

Data length

8 bit (fixed)

Start bit

1 bit (fixed)

Stop bit

1 bit (fixed)

To configure the setup of the communication using NETWORK BRIDGE for
the projector, use items in the COMMUNICATION menu. Open the menu of
the projector and select the OPTION - SERVICE - COMMUNICATION menu.
(

OPTION menu - SERVICE – COMMUNICATION in the User's Manual -

Operating Guide)