Marantz 3-Head Double Cassette Deck PMD520 User Manual

Page 12

Advertising
background image

11

English

English

CONTINUOUS RECORDING

1. Insert blank cassettes into both Wells. Be sure that both decks

are rewound.

2. If you wish to use noise reduction, set the

DOLBY NR

switches

accordingly.

3. Reset the tape counters to "00.00" by pressing the

RESET

buttons.

4. Press the

CONT

button. Pressing it once sets the "

" mode,

in which the indicator lights up. Pressing it twice sets the
"

" mode, in which the indicator blinks.

5. Press the

REC

buttons of both wells to enter REC-PAUSE

mode.

6. Adjust the record level using the

REC LEVEL

control.

7. Press the

PLAY

button on Well A to initiate RECORD.

8. When the tape in Well A is finished, recording starts auto-

matically in Well B. If the continuous mode is "

", recording

ends when tape in Well B is finished and another deck is
triggered with the EXT output. If the continuous mode is "

",

recording in Well A restarts at the moment recording in Well
B is finished. At this time, the tape in Well A should be re-
versed manually or replaced with a new tape.

9. Press

STOP

button to end the Recording.

10. Press the

CONT

button to cancel continuous mode.

Note:

All input for continuous recording will come from Line In-
put A.

PARALLEL RECORDING

1. Insert blank cassettes into both Wells. Be sure that both decks

are rewound.

2. If you wish to use noise reduction, set the

DOLBY NR

switches

accordingly.

3. Reset the tape counters to “00.00” by pressing the

RESET

buttons.

4. Press the

A+B REC

button. This will set both Wells for record,

and the REC lights will blink.

5. Adjust the record level using the

REC LEVEL

control.

6. Press the

A+B

button again to start the recording.

7. Press both

STOP

buttons to stop recording, or press the

A+B

button to re-enter record-pause mode.

Note:

All input for parallel recording will come from Line Input A.

TIMER RECORDING
(Same procedure for Wells A and B)

1. Connect the power cord of this unit to a timer.

2. Insert a blank cassette in the cassette holder(s).

3. Set the

POWER

button to on.

4. If you wish to use Dolby NR in your recording, set the

DOLBY

NR

switches to select B- or C-type noise reduction.

5. Press the

REC

button to enter record-pause mode.

6. While observing the level meter, adjust the

REC LEVEL

Con-

trol.

7. Set the

TIMER

switch to the REC position.

8. Set the timer to the desired time.

9. When the set time comes and the timer turns on, power is

supplied to the unit and recording starts automatically.

Note:

Use a timer which can turn on at the desired time of the day.

OVERLAP SERIES RECORDING

1. Insert blank cassettes in the cassette holders of both wells.

2. Press the

CONT

button. Pressing it once sets the "

" mode,

in which the indicator lights up. Pressing it twice sets the
"

" mode, in which the indicator blinks.

3. Press the

OVERLAP REC

button. The OVERLAP REC indi-

cator lights up to indicate the overlap series recording mode.

4. Press the

REC

buttons of Wells A and B to enter record-

pause mode.

5. In record-pause mode, adjust the

REC LEVEL

controls of

both wells.

6. Press the

PLAY

button of Well A or B to start recording.

7. When the remaining time on the tape in the first Well is ap-

proximately 3 minutes, the other well starts recording auto-
matically.

8. If the auto rewind mode is switched on, the finished tape is

rewound automatically to the beginning. If the auto rewind
mode is off, reverse the finished tape manually to prepare
for the next recording.

9. To terminate the overlap series recording mode, press the

OVERLAP REC

button again.

Note:

If AUTO REW is activated during the "

" mode or the con-

tinuous loop is fed back to the first deck, the information re-
corded will be erased and recorded over.

Advertising