Inflating the lp, Manual inflation, Auto-inflation – Mustang Survival MD1250 User Manual

Page 7: Oral inflation, Special considerations

Advertising
background image

2. Release the attachment webbing straps on the back of the LP by pulling

up on each strap just below the bottom edge of the pull-the-dot snap.

3. Feed the attachment webbing straps on the back of the LP through the

PALS webbing.

4. Reattach the pull-the-dot snaps by pushing down on the top edge of

the snap opposite the dot.

inflating the lP

WaRning: When using the MD1250 lP in temperatures below freezing,
fully discharging the co

2

cylinder may not provide adequate inflation. to

compensate, use the oral inflator tube to top-up the lP.

note: after inflating both MD1250 lPs, secure them to each other with
the Velcro

® attachment straps on the forward edge of each inflation cell.

Manual inflation

To manually activate the hydrostatic inflator, jerk firmly downward on the
beaded manual inflation handle. The LP should inflate within five seconds.

auto-inflation

caution: if the MD1250 lP has been orally inflated, co

2

inflation could

over-pressurize and damage it.

When the uninflated LP is submerged in water, the hydrostatic inflator
releases CO

2

into the inflation cell, inflating the LP.

Special considerations

Auto-inflation of the LP may create a risk of damage under the following
circumstances:

Double inflation—CO

2

cylinder inflation after full oral inflation.

Inflation while stored in a tight space.

Inflation while in an awkward place or position.

oral inflation

Although a properly armed LP will correctly inflate manually or
automatically, the inflation CO

2

escapes slowly through the fabric and

a slight reduction in pressure is apparent several hours after inflation.
Therefore, oral top-up inflation may be required during prolonged
immersion (or in a non-emergency situation). To orally inflate the LP:
1. If necessary, open the zippers completely, and unfold the inflation cell.
2. Locate the oral inflation tube, and turn the locking ring clockwise to

open the inflator valve and unlock the mouthpiece.

3. Press (and hold) the mouthpiece down, and blow into the tube until the

LP is fully inflated.

Tactical Inflatable Side Pouch LP

Owners Manual

4

Advertising