Installation instructions – Miele KM88-2 User Manual

Page 16

Advertising
background image

Installation instructions

This appliance is classified as ”Y“ class
for heat protection. There may be a wall
at the rear and a wall or tall cabinet at
one side. On the other side, however,
no cabinet or wall must stand higher
than the grill.

There must be a minimum distance
of 9-7/8" (250 mm) between the ap-
pliance and adjacent cabinetry, be-
cause of the heat radiated from the
elements.

Prepare the countertop cut-out as il-
lustrated.
Dimension ”B“ will vary depending on
how many combisets are installed.
The following chart gives dimension
”B“ for a variety of 2 zone (ie KM 88-2)
and 4 zone (ie KM 93-2) combinations.

Depth

in

mm

Width *

(= Dimen-

sion B)

in mm

2 zone Combiset

1 Combiset
2 Combisets
3 Combisets
4 Combisets
5 Combisets

490
490
490
490
490

265
558
851

1144
1437

4 zone Combiset

1 Combiset
2 Combisets
3 Combisets

490
490
490

560

1143
1728

Combination

One 2 zone
+ one 4 zone

Two 2 zone
+ one 4 zone

Three 2 zone
+ one 4 zone

One 2 zone
+ two 4 zone

Two 2 zone
+ two 4 zone

490

490

490

490

490

851

1143

1437

1436

1729

Extractor (e.g. DA 8-2)

For building in between two
appliances:
-

Dimension

B

increases by 90 mm.

For building in at the end of a
combination:
-

Dimension

B

increases by 98 mm.

* Width includes provision for V 98 spacer bar

.

2-3/16"

19-5/16"

2-3/16"’

Installation instructions

16

Advertising