Motorola LD-W-1 User Manual

Page 14

Advertising
background image

LD-G-1 / LD-W-1

English

Page 31

§

Standard or second velocity characteristics

§

Shunting gear active or inactive

§

Fast, medium or slow acceleration and brake delay

The setting of the delay can be combined with any setting of the
velocity characteristic and the shunting gear.
The setting is made by attaching solder bridges to X17 (on the front of
the decoder, underneath the IC U1) and to X20 (on the front of the
decoder, to the left of IC U1). The assignment is as follows:

Connection

Operation

X17 Pin 1: no solder bridge

Standard velocity characteristic +
shunting gear active, switched via F4

X17 Pin 1 - X 20

Second velocity characteristic +
shunting gear inactive

X17 Pin 1 - X 17 Pin 2

Standard velocity characteristic +
shunting gear inactive

X17 Pin 3: no solder bridge

Fast delay

X17 Pin 3 - X 20

Slow delay

X17 Pin 3 - X 17 Pin 2

Medium delay

Example:
Adjusting the second velocity
characteristic and the medium
acceleration and brake delay

Setting the locomotive address
The locomotive decoder can be set to one of 255 addresses. The
setting is made by mounting solder bridges to X13 - X17 (on the front
of the decoder, left of the IC U1) resp. X18 on the front of the decoder,
right of the IC U1). The assignment is shown in the list on page 68.
The solder pads are numbered from the left side of the PCB as follows:

1

2

3

Advertising