20

A

PPENDIX

A

(

CONTINUED

)

E

LECTRICAL

Input Voltage

5 VDC ± 0.25 V

Power - Operating

800 mW

Current - Operating

160 mA peak @ 5 VDC

DC Transformers

Class 2; 5.2 V @ 650 mA

UL

UL listed for US and Canada;
UL 1950, C22.2 No. 950

Laser Class

CDRH: Class II; EN60825-1:1994/A11:1996 Class 1

EMC

FCC, ICES-003 & EN 55022 Class A

E

NVIRONMENTAL

Operating
Temperature

0°C to 40°C (32°F to 104°F)

Storage Temperature

-40°C to 60°C (-40°F to 140°F)

Humidity

5% to 95% relative humidity, non-condensing

Light Levels

Up to 4842 Lux (450 footcandles)

Shock

Designed to withstand 1.5 m (5’) drops

Contaminants

Sealed to resist airborne particulate contaminants

Ventilation

None required