Ac d b, Fireplace and hearth dimensions, Warning – Monessen Hearth TPB18 User Manual

Page 9

Advertising
background image

70D0004

9

A

C

D

B

FIREPLACE AND HEARTH DIMENSIONS

Use manufacturer's installation and clearance requirements as defined in their manual.
The TPB Series unvented room heater is approved for installation into the following unvented fireplaces:

GCUF Series Fireboxes Magnum36/42, Lo-Rider36

or BUF

The TPB Series unvented room heater may also be installed into a Ventless Firebox Enclosure for Gas Fired

Decorative Type Unvented Room Heaters per IAS Requirement No. 2-97 ANSI Z21.91-2001 (typically referred

to as a "Universal Firebox"), as long as firebox hearth dimensions meet the minimum hearth dimensions shown

below.

Figure 2 - Hearth Minimum Dimension

This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-
built fireplace, vent free appliance, or in listed ventless firebox enclosure. It has been
design certified for these installations.
Exception:
DO NOT install this appliance in a factory-built fireplace that includes
instructions stating it has not been tested or should not be used with unvented gas
logs.

W

ARNING

Model

A

B*

C

D

TPB18

26"

13"

18"

17"

TPB24

29"

13"

22

1

/

4

"

17"

TPB30

33"

13"

25

1

/

4

"

17"

* Without front grate installed "B" will be 12 ½.

Advertising