Multiquip MQ Power Whisperwatt 50 Hz Generator DCA10SPXU4 User Manual

Page 22

Advertising
background image

PAGE 22 — DCA10SPX4/DCA10SPXU4 — OPERATION AND PARTS MANUAL — REV. #0 (08/05/09)

100 VAC GFCI Receptacle

This100 VAC, 20 amp GFCI (Duplex Nema 5-20R)
receptacle can be used anytime the generator is in operation.
The receptacle is protected by a 20 amp circuit breaker.
The breaker can be located on the generator control panel.

Pressing the

reset button resets the GFCI receptacle after

being tripped. Pressing the

Test Button (See Figure 6) in

the center of the receptacle will check the GFCI function.
This receptacle should be tested at least once a month.

Figure 6. G.F.C.I. Receptacle

Turn the

voltage regulator control knob (Figure 10) on

the control panel to obtain the desired voltage. Turning the
knob clockwise will

increase the voltage, turning the knob

counter-clockwise will

decrease the voltage.

Figure 7. CS6369 Twist-Lock

Auxiliary Receptacle

DCA-10SPX4 /U4 — OUTPUT TERMINAL PANEL FAMILIARIZATION

Twist Lock Dual Voltage 100/200 VAC Receptacle (Option)

There is one CS-6369 100/200V, 45 amp auxilliary twist-
lock receptacle (Figure 7) provided on the output terminal
panel. This receptacle is protected by a 45 amp circuit
breaker.

Figure 10. Voltage Regulator Control Knob

L5-30R Twist Lock 100 VAC Receptacle (Option)

There is one L5-30R, 100 VAC 30 amp auxilliary twist-lock
receptacle (Figure 8) provided on the output terminal panel.
This receptacle is protected by a 30 amp circuit breaker.

L6-30R Twist Lock 200 VAC Receptacle (Option)

There is one L6-30R, 200 VAC 30 amp auxilliary twist-lock
receptacle (Figure 9) provided on the output terminal panel.
This receptacle is protected by a 30 amp circuit breaker.

Figure 8. L5-30R Twist-Lock

Auxiliary Receptacle