Installation site, Confined space installation – Miele T 9822 User Manual

Page 10

Advertising
background image

Confined space installation

^ When installed in any space with less

than 122 square feet (11.3 m

2

),

minimum clearances around the
dryer must be adhered to for proper
ventilation and vents for make up air
must be installed.

^ Do not install any other fuel-burning

appliance in the same space as the
dryer.

Confined door openings

Any doors limiting circulation must be
louvered or otherwise ventilated.
A minimum of 72 square inches
(465 cm

2

) of opening is required. It

must be equally divided within 3"
(7.6 cm) from the top and bottom of the
door.

Minimum installation clearance

Sides: 0 " (0 cm)

Top:

12" (30.5 cm)

Rear: 0" (0 cm) (as close to wall as
gas connection and venting allows)

Front to door: 2" (5 cm)
Make sure the dryer door can open
completely once installed.

Exhaust duct clearance
to combustible material: 2" (5 cm)

Installation site

10

Advertising