Maintenance

The capsule hopper in the brew unit
needs to be replaced after about
15,000 cups of coffee. Replacement
capsule hoppers are available from the
Miele Spare Parts Dept.

Settings F
K1 K2 K3 K4 K5 L o n G k

C

^ Select "Settings

F" from the Main

menu, and then touch the OK sensor.

^ Use the arrow sensors to highlight

"Maintenance", and then touch the
OK sensor.

^ Select "Carry out" and touch the OK

sensor.

The capsule hopper inside the machine
will be lowered. The following will then
appear in the display:

i Remove capsule plate and change

the capsule hopper

^ Open the front of the machine.

^ Take out the capsule plate.

Do not reach into the openings in
the brew unit. Danger of injury.

^ Pull the rubber connector

downwards.

^ Using the special tool (supplied) as

shown above, turn the capsule
hopper to the left to remove it.

^ Screw the new capsule hopper to the

right into position in the brew unit, as
shown above. The spring with the
ball in the capsule hopper must be
placed so that the ball is at the top.

^ Put the rubber connector back on

from below (the narrow end or funnel
towards the bottom).

^ Insert the capsule plate and close the

machine front.

Cleaning and care